Literature DB >> 16086321

Processing of radial fast spin-echo data for obtaining T2 estimates from a single k-space data set.

Maria I Altbach1, Ali Bilgin, Zhiqiang Li, Eric W Clarkson, Theodore P Trouard, Arthur F Gmitro.   

Abstract

Radially acquired fast spin-echo data can be processed to obtain T2-weighted images and a T2 map from a single k-space data set. The general approach is to use data at a specific TE (or narrow TE range) in the center of k-space and data at other TE values in the outer part of k-space. With this method high-resolution T2-weighted images and T2 maps are obtained in a time efficient manner. The mixing of TE data, however, introduces errors in the T2-weighted images and T2 maps that affect the accuracy of the T2 estimates. In this work, various k-space data processing methods for reconstructing T2-weighted images and T2 maps from a single radial fast spin-echo k-space data set are analyzed in terms of the accuracy of T2 estimates. The analysis is focused on the effect of image artifacts, object dependency, and noise on the T2 estimates. Results are presented in computer-generated phantoms and in vivo. Copyright (c) 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16086321     DOI: 10.1002/mrm.20611

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

2.  Ultrafast compartmentalized relaxation time mapping with linear algebraic modeling.

Authors:  Yi Zhang; Xiaoyang Liu; Jinyuan Zhou; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2017-04-11       Impact factor: 4.668

3.  Experimental O-space turbo spin echo imaging.

Authors:  Haifeng Wang; Leo Tam; Emre Kopanoglu; Dana C Peters; R Todd Constable; Gigi Galiana
Journal:  Magn Reson Med       Date:  2015-05-15       Impact factor: 4.668

4.  T2 relaxometry with indirect echo compensation from highly undersampled data.

Authors:  Chuan Huang; Ali Bilgin; Tomoe Barr; Maria I Altbach
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

5.  Accelerated and motion-robust in vivo T2 mapping from radially undersampled data using bloch-simulation-based iterative reconstruction.

Authors:  Noam Ben-Eliezer; Daniel K Sodickson; Timothy Shepherd; Graham C Wiggins; Kai Tobias Block
Journal:  Magn Reson Med       Date:  2015-04-17       Impact factor: 4.668

6.  T1 mapping, T2 mapping and MR elastography of the liver for detection and staging of liver fibrosis.

Authors:  David H Hoffman; Abimbola Ayoola; Dominik Nickel; Fei Han; Hersh Chandarana; Krishna Prasad Shanbhogue
Journal:  Abdom Radiol (NY)       Date:  2020-03

7.  In vivo assessment of neurodegeneration in Niemann-Pick type C mice by quantitative T2 mapping and diffusion tensor imaging.

Authors:  John W Totenhagen; Silvia Lope-Piedrafita; Ivan A Borbon; Eriko S Yoshimaru; Robert P Erickson; Theodore P Trouard
Journal:  J Magn Reson Imaging       Date:  2011-11-01       Impact factor: 4.813

8.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

Authors:  Daniel Neumann; Felix A Breuer; Michael Völker; Tobias Brandt; Mark A Griswold; Peter M Jakob; Martin Blaimer
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

10.  Rapid water and lipid imaging with T2 mapping using a radial IDEAL-GRASE technique.

Authors:  Zhiqiang Li; Christian Graff; Arthur F Gmitro; Scott W Squire; Ali Bilgin; Eric K Outwater; Maria I Altbach
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.