[On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT].

T Flohr1, B Ohnesorge, K Stierstorfer, H Bruder, J Simon, C Süss, J Wildberger, U Baum, M Lell, A Küttner, M Heuschmid, B Wintersperger, C Becker, S Schaller.   

Abstract

The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging.

Entities:  

Mesh:

Year:  2005        PMID: 16059657     DOI: 10.1007/s00117-003-0944-1

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  21 in total

1.  Single-slice rebinning reconstruction in spiral cone-beam computed tomography.

Authors:  H Bruder; M Kachelriess; S Schaller; K Stierstorfer; T Flohr
Journal:  IEEE Trans Med Imaging       Date:  2000-09       Impact factor: 10.048

2.  Noninvasive detection of coronary artery stenosis by multislice helical computed tomography.

Authors:  A Knez; C Becker; B Ohnesorge; R Haberl; M Reiser; G Steinbeck
Journal:  Circulation       Date:  2000-06-13       Impact factor: 29.690

3.  Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.

Authors:  S Achenbach; S Ulzheimer; U Baum; M Kachelriess; D Ropers; T Giesler; W Bautz; W G Daniel; W A Kalender; W Moshage
Journal:  Circulation       Date:  2000-12-05       Impact factor: 29.690

4.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

5.  ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart.

Authors:  M Kachelriess; S Ulzheimer; W A Kalender
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

6.  Journey toward computer-aided diagnosis: role of image texture analysis.

Authors:  G D Tourassi
Journal:  Radiology       Date:  1999-11       Impact factor: 11.105

7.  Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart.

Authors:  T Flohr; B Ohnesorge
Journal:  J Comput Assist Tomogr       Date:  2001 Nov-Dec       Impact factor: 1.826

8.  Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography.

Authors:  S Schroeder; A F Kopp; A Baumbach; C Meisner; A Kuettner; C Georg; B Ohnesorge; C Herdeg; C D Claussen; K R Karsch
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

9.  Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.

Authors:  Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

10.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

View more
  1 in total

1.  Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: initial results.

Authors:  Miriam Klauss; Max Schöbinger; Ivo Wolf; Jens Werner; Hans-Peter Meinzer; Hans-Ulrich Kauczor; Lars Grenacher
Journal:  World J Gastroenterol       Date:  2009-12-14       Impact factor: 5.742

  1 in total