Short communication: Setup variations in locoregional radiotherapy for breast cancer: an electronic portal imaging study.

P T Truong1, E Berthelet, V Patenaude, J Bishop, B Sandwith, V Moravan, W Beckham, T Mitchell, I A Olivotto.   

Abstract

Recent trials demonstrating a survival benefit with locoregional radiotherapy (LRRT) to the chest wall and regional nodes in women with node-positive breast cancer have led to increased use of complex techniques to match three or more radiation fields, but information on setup reproducibility with LRRT for breast cancer is scarce. This study reports the magnitude and directions of random and systematic deviations in LRRT for breast cancer using an offline electronic portal imaging verification protocol. Electronic portal images (EPIs) of 46 consecutive women treated with LRRT for breast cancer from March 2001 to February 2002 with LRRT were analysed. Comparisons of EPIs to the corresponding digitally reconstructed radiographs were performed offline with anatomy matching. Displacements in mm were recorded in the superior-inferior (SI), medial-lateral (ML), and anterior-posterior (AP) directions. Random errors ranged from 2.0 mm to 2.5 mm for the breast/chest wall tangential treatments and 2.3 mm to 3.9 mm for the supraclavicular nodal treatments. Systematic errors occurred to a greater degree in the AP direction for the tangential fields and in the ML direction for the supraclavicular field. Displacements of > or =10 mm were found in 1.2% of breast/chest wall tangential treatments and in 6.2% of supraclavicular nodal treatments. These data demonstrate that EPI is a useful tool to verify setup reproducibility in LRRT for breast cancer.

Entities:  

Mesh:

Year:  2005        PMID: 16046427     DOI: 10.1259/bjr/11782857

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Comparison of set-up errors by breast size on wing board by portal imaging.

Authors:  Waseem Raza; Sushma Agarwal; Koilpillai Joseph Maria Das; Sellepolyam Kaliyaperumal Senthil Kumar; Punita Lal
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-06

2.  Correction of systematic set-up error in breast and head and neck irradiation through a no-action level (NAL) protocol.

Authors:  Eva M Lozano; Luis A Pérez; Javier Torres; Carmen Carrascosa; Miguel Sanz; Fermín Mendicote; Antonio Gil
Journal:  Clin Transl Oncol       Date:  2011-01       Impact factor: 3.405

3.  Dosimetric and isocentric variations due to patient setup errors in CT-based treatment planning for breast cancer by electronic portal imaging.

Authors:  Hari Mukundan; Deboleena Mukherjee; Kirti Tyagi; Sachin Taneja; Subhash Ranjan; Samaresh Sahu
Journal:  Med J Armed Forces India       Date:  2018-10-15

4.  A three-field monoisocentric inverse breast treatment planning technique without half-beam blocking.

Authors:  Tiezhi Zhang; Joshua T Dilworth; Ovidiu Marina; Peter Chen; Lisa Benedetti; Qiang Liu
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

  4 in total