Literature DB >> 16040924

Metallic prosthesis: technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients.

Tejas Dalal1, Mannudeep K Kalra, Stefania M R Rizzo, Bernhard Schmidt, Christoph Suess, Thomas Flohr, Michael A Blake, Sanjay Saini.   

Abstract

The institutional review board approved this Health Insurance Portability and Accountability Act-compliant study protocol, with waiver of informed consent. The purpose of the study was to retrospectively evaluate the combined automatic tube current modulation technique in patients with orthopedic metallic prostheses. Five hundred abdominal-pelvic computed tomographic (CT) studies performed with combined modulation technique were reviewed to identify nine patients with metallic prostheses (mean age, 66 years; range, 35-86 years; male-female ratio, 5:4). On the basis of age and transverse abdominal images, these patients were matched with nine others with no metallic prostheses (mean age, 56 years; range, 36-72 years; male-female ratio, 4:5) who were control patients. Images were graded for extent and severity of streak artifacts (grade 1, streak artifact present but not substantially compromising evaluation of adjacent structures; grade 2, streak artifact present and slightly compromising evaluation of adjacent structures; and grade 3, streak artifact present and severely compromising evaluation of adjacent structures). Student t test was performed for statistical analysis. There was no difference in mean effective tube current-time product between study and control patients (P > .49). With automatic tube current modulation, an increase in CT dose caused by metallic prostheses can be successfully avoided.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16040924     DOI: 10.1148/radiol.2362041565

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

1.  Automatic tube current modulation technique for multidetector CT: is it effective with a 64-detector CT?

Authors:  Yoshinori Funama; Kazuo Awai; Masahiro Hatemura; Masamitchi Shimamura; Yumi Yanaga; Seitaro Oda; Yasuyuki Yamashita
Journal:  Radiol Phys Technol       Date:  2007-11-01

2.  Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation.

Authors:  Hyun Woo Goo; Hyum Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-02-25

Review 3.  Computed tomography dose optimisation in cystic fibrosis: A review.

Authors:  Helena Ferris; Maria Twomey; Fiachra Moloney; Siobhan B O'Neill; Kevin Murphy; Owen J O'Connor; Michael Maher
Journal:  World J Radiol       Date:  2016-04-28

Review 4.  Current applications of advanced cross-sectional imaging techniques in evaluating the painful arthroplasty.

Authors:  Carolyn M Sofka
Journal:  Skeletal Radiol       Date:  2006-12-06       Impact factor: 2.199

5.  Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter.

Authors:  Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Taiga Goto; Yoshiharu Nakayama; Masamitchi Shimamura; Kumiko Hiraishi; Shinichi Hori; Yasuyuki Yamashita
Journal:  Radiat Med       Date:  2008-04

6.  Body composition assessment: comparison of quantitative values between magnetic resonance imaging and computed tomography.

Authors:  Chiara Zaffina; Rolf Wyttenbach; Alberto Pagnamenta; Rosario Francesco Grasso; Matteo Biroli; Filippo Del Grande; Stefania Rizzo
Journal:  Quant Imaging Med Surg       Date:  2022-02

7.  Beam hardening artifacts by dental implants: Comparison of cone-beam and 64-slice computed tomography scanners.

Authors:  Farzad Esmaeili; Masume Johari; Pezhman Haddadi
Journal:  Dent Res J (Isfahan)       Date:  2013-05

8.  A questionnaire survey reviewing radiologists' and clinical specialist radiographers' knowledge of CT exposure parameters.

Authors:  S J Foley; M G Evanoff; L A Rainford
Journal:  Insights Imaging       Date:  2013-09-05

9.  Effect of Dental Implant Metal Artifacts on Accuracy of Linear Measurements by Two Cone-Beam Computed Tomography Systems Before and After Crown Restoration.

Authors:  Hoorieh Bashizadeh Fakhar; Roxana Rashtchian; Milad Parvin
Journal:  J Dent (Tehran)       Date:  2017-11

10.  A cancer-mimicking diagnosis of peritoneal carcinosis: report of a case of abdominal non-tuberculous mycobacterial infection.

Authors:  Francesca De Piano; Filippo Savoldi; Francesca Ruju; Mariacristina Ghioni; Vanna Zanagnolo; Stefania Rizzo
Journal:  Ecancermedicalscience       Date:  2018-08-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.