Literature DB >> 16040111

Minimization of the inevitable residual monomer in denture base acrylic.

C Y K Lung1, B W Darvell.   

Abstract

OBJECTIVES: Residual monomer ([MMA](R)) in denture base acrylic continues to be of concern. The response surface of concentration vs. time and temperature for the equilibration of methyl methacrylate (MMA) and its polymer (PMMA) allows a prediction of the time to the minimum at any temperature for a closed system. It was the purpose here to determine whether this prediction applies to normal denture base processing, and whether optimum conditions could be identified.
METHODS: Denture bases were processed following normal laboratory procedures, including pre-cure for 3 h at 70 degrees C for all tests. Commercial powder and liquid were used at either 95 or 100 degrees C, or a plain PMMA powder and the same liquid at 95 degrees C, for times ranging from 5 to 192 h. Residual MMA was determined by gas chromatography.
RESULTS: [MMA](R) decreased steadily from approximately 0.25% to as low as approximately 0.07% with increasing time at temperature, but did not approach equilibrium. The rate of diffusive loss of MMA appears to exceed the rate of depolymerization. SIGNIFICANCE: Residual monomer is inevitable for all PMMA-based products no matter what the curing conditions are. However, extended time at high temperature can allow low values to be attained, and the time allowed can compensate for processing temperatures somewhat lower than the ordinarily recommended 100 degrees C. It is suggested that overnight processing at 95 degrees C should be adopted to minimize [MMA](R) and save energy. This result is of importance for work at high altitude.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16040111     DOI: 10.1016/j.dental.2005.03.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  11 in total

1.  Plasticizers and Salt Concentrations Effects on Polymer Gel Electrolytes Based on Poly (Methyl Methacrylate) for Electrochemical Applications.

Authors:  Carmen Rizzuto; Dale C Teeters; Riccardo C Barberi; Marco Castriota
Journal:  Gels       Date:  2022-06-08

Review 2.  Titanium Dental Implants: An Overview of Applied Nanobiotechnology to Improve Biocompatibility and Prevent Infections.

Authors:  Rayane C S Silva; Almerinda Agrelli; Audrey N Andrade; Carina L Mendes-Marques; Isabel R S Arruda; Luzia R L Santos; Niedja F Vasconcelos; Giovanna Machado
Journal:  Materials (Basel)       Date:  2022-04-27       Impact factor: 3.748

3.  In Vitro Analysis of the Mechanical Properties of Hypoallergenic Denture Base Resins.

Authors:  Sebastian Hinz; Tobias Bensel; Wolfgang Bömicke; Arne F Boeckler
Journal:  Materials (Basel)       Date:  2022-05-18       Impact factor: 3.748

4.  The Boston Keratoprosthesis: comparing corneal epithelial cell compatibility with titanium and PMMA.

Authors:  Jared D Ament; Sandra J Spurr-Michaud; Claes H Dohlman; Ilene K Gipson
Journal:  Cornea       Date:  2009-08       Impact factor: 2.651

5.  Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles.

Authors:  Canan Bural; Esin Aktaş; Günnur Deniz; Yeşim Ünlüçerçi; Gülsen Bayraktar
Journal:  J Appl Oral Sci       Date:  2011-05-27       Impact factor: 2.698

Review 6.  Allergic effects of the residual monomer used in denture base acrylic resins.

Authors:  Haroon Rashid; Zeeshan Sheikh; Fahim Vohra
Journal:  Eur J Dent       Date:  2015 Oct-Dec

7.  Do CAD/CAM dentures really release less monomer than conventional dentures?

Authors:  Patricia-Anca Steinmassl; Verena Wiedemair; Christian Huck; Florian Klaunzer; Otto Steinmassl; Ingrid Grunert; Herbert Dumfahrt
Journal:  Clin Oral Investig       Date:  2016-10-05       Impact factor: 3.573

8.  Determination of Polyetheretherketone (PEEK) mechanical properties as a denture material.

Authors:  Saja A Muhsin; Paul V Hatton; Anthony Johnson; Nuno Sereno; Duncan J Wood
Journal:  Saudi Dent J       Date:  2019-03-13

9.  Toxicological Assessment of an Acrylic Removable Orthodontic Appliance Using 2D and 3D In Vitro Methods.

Authors:  Stefania Dinu; Emanuela Lidia Craciunescu; Ioana Macasoi; Doina Chioran; Mircea Rivis; Daliborca Vlad; Raluca Adriana Milutinovici; Iasmina Marcovici; Alina Dolghi; Alina Moaca; Dorin Cristian Dinu; Cristina Dehelean; Malina Popa
Journal:  Materials (Basel)       Date:  2022-02-04       Impact factor: 3.623

10.  The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials.

Authors:  Nick Polychronakis; Maria Dimitriadi; Gregory Polyzois; George Eliades
Journal:  J Appl Oral Sci       Date:  2022-07-22       Impact factor: 3.144

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.