Literature DB >> 16028882

Evaluation of mycological contamination of dental unit waterlines.

Jolanta Szymańska1.   

Abstract

The quality of dental unit water is of great importance since patients and dental staff are regularly exposed to water from aerosols generated during work. The main purpose of this investigation was mycological evaluation of dental unit waterlines (DUWL). The author determined the number and species of fungi present in the water from a unit reservoir which is the source of water for a dental unit, in the water flowing from a high-speed handpiece of a unit, and in the swab sample collected from the wall of a waterline connecting a unit reservoir and dental handpieces. The following mould fungi were identified: Aspergillus amstelodami, Aspergillus fumigatus, Aspergillus spp. from Aspergillus glaucus group, Aspergillus repens, Citromyces spp., Geotrichum candidum, Penicillium aspergilliforme, Penicillium pusillum, Penicillium turolense, Sclerotium sclerotiorum; yeast-like fungi: Candida albicans, Candida curvata and other yeasts. Some of them, in certain circumstances, especially in people with immunological disorders, may be a cause of opportunistic infections. Thus, it is necessary that the DUWL should be submitted to a decontamination protocol and to routine microbial monitoring to guarantee an appropriate quality of water used in dental treatment.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16028882

Source DB:  PubMed          Journal:  Ann Agric Environ Med        ISSN: 1232-1966            Impact factor:   1.447


  10 in total

1.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

Review 2.  Monitoring dental-unit-water-line output water by current in-office test kits.

Authors:  Sham Lal; Sim K Singhrao; Matt Bricknell; Mark Pearce; L H Glyn Morton; Waqar Ahmed; St John Crean
Journal:  Curr Microbiol       Date:  2014-03-25       Impact factor: 2.188

3.  Fatal brain infection caused by Aspergillus glaucus in an immunocompetent patient identified by sequencing of the ribosomal 18S-28S internal transcribed spacer.

Authors:  R S Traboulsi; M M Kattar; O Dbouni; G F Araj; S S Kanj
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2007-10       Impact factor: 3.267

4.  A 10-year survey of compliance with recommended procedures for infection control by dentists in Beijing.

Authors:  Jing Su; Xiao-Hong Deng; Zheng Sun
Journal:  Int Dent J       Date:  2012-03-12       Impact factor: 2.607

5.  Microbial quality of water in dental unit waterlines.

Authors:  Mahnaz Nikaeen; Maryam Hatamzadeh; Zohre Sabzevari; Omolbanin Zareh
Journal:  J Res Med Sci       Date:  2009-09       Impact factor: 1.852

6.  Risk of Fungal Infection to Dental Patients.

Authors:  Jaqueline Lopes Damasceno; Rafael Aparecido Dos Santos; Amir Horiquini Barbosa; Luciana Assirati Casemiro; Regina Helena Pires; Carlos Henrique Gomes Martins
Journal:  ScientificWorldJournal       Date:  2017-06-14

7.  Effectiveness and safety of low-concentrated ozonized water for the reduction of contamination in dental unit water lines.

Authors:  Keisuke Okubo; Takashi Ito; Yasuyoshi Shiota; Yusuke Kawata; Tadashi Yamamoto; Shogo Takashiba
Journal:  Heliyon       Date:  2019-08-21

8.  Distinct Microbial Community of Accumulated Biofilm in Dental Unit Waterlines of Different Specialties.

Authors:  Cancan Fan; Haijing Gu; Limin Liu; Haiwei Zhu; Juan Yan; Yongbiao Huo
Journal:  Front Cell Infect Microbiol       Date:  2021-06-17       Impact factor: 5.293

9.  Risk assessment for the spread of Candida sp. in dental chair unit waterlines using molecular techniques.

Authors:  Wissame Mazari; Zahia Boucherit-Otmani; Imad Abdelhamid El Haci; Amine Ilahi; Kebir Boucherit
Journal:  Int Dent J       Date:  2018-05-04       Impact factor: 2.607

10.  Mycological contamination in dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay Kadaifciler; Suzan Ökten; Burhan Sen
Journal:  Braz J Microbiol       Date:  2014-01-15       Impact factor: 2.476

  10 in total