Literature DB >> 16024179

A novel 3D volumetric voxel registration technique for volume-view-guided image registration of multiple imaging modalities.

Guang Li1, Huchen Xie, Holly Ning, Jacek Capala, Barbara C Arora, C Norman Coleman, Kevin Camphausen, Robert W Miller.   

Abstract

PURPOSE: To provide more clinically useful image registration with improved accuracy and reduced time, a novel technique of three-dimensional (3D) volumetric voxel registration of multimodality images is developed. METHODS AND MATERIALS: This technique can register up to four concurrent images from multi-modalities with volume view guidance. Various visualization effects can be applied, facilitating global and internal voxel registration. Fourteen computed tomography/magnetic resonance (CT/MR) image sets and two computed tomography/positron emission tomography (CT/PET) image sets are used. For comparison, an automatic registration technique using maximization of mutual information (MMI) and a three-orthogonal-planar (3P) registration technique are used.
RESULTS: Visually sensitive registration criteria for CT/MR and CT/PET have been established, including the homogeneity of color distribution. Based on the registration results of 14 CT/MR images, the 3D voxel technique is in excellent agreement with the automatic MMI technique and is indicatory of a global positioning error (defined as the means and standard deviations of the error distribution) using the 3P pixel technique: 1.8 degrees +/- 1.2 degrees in rotation and 2.0 +/- 1.3 (voxel unit) in translation. To the best of our knowledge, this is the first time that such positioning error has been addressed.
CONCLUSION: This novel 3D voxel technique establishes volume-view-guided image registration of up to four modalities. It improves registration accuracy with reduced time, compared with the 3P pixel technique. This article suggests that any interactive and automatic registration should be safe-guarded using the 3D voxel technique.

Mesh:

Year:  2005        PMID: 16024179     DOI: 10.1016/j.ijrobp.2005.05.008

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  10 in total

1.  Fast three-dimensional superimposition of cone beam computed tomography for orthopaedics and orthognathic surgery evaluation.

Authors:  A Weissheimer; L M Menezes; L Koerich; J Pham; L H S Cevidanes
Journal:  Int J Oral Maxillofac Surg       Date:  2015-04-29       Impact factor: 2.789

2.  GPU-based fast gamma index calculation.

Authors:  Xuejun Gu; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2011-02-11       Impact factor: 3.609

3.  Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate.

Authors:  Guang Li; Naveen C Arora; Huchen Xie; Holly Ning; Wei Lu; Daniel Low; Deborah Citrin; Aradhana Kaushal; Leor Zach; Kevin Camphausen; Robert W Miller
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

4.  Characterization of optical-surface-imaging-based spirometry for respiratory surrogating in radiotherapy.

Authors:  Guang Li; Jie Wei; Hailiang Huang; Qing Chen; Carl P Gaebler; Tiffany Lin; Amy Yuan; Andreas Rimner; James Mechalakos
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

5.  Biomechanical model for computing deformations for whole-body image registration: A meshless approach.

Authors:  Mao Li; Karol Miller; Grand Roman Joldes; Ron Kikinis; Adam Wittek
Journal:  Int J Numer Method Biomed Eng       Date:  2016-03-14       Impact factor: 2.747

6.  Clinical Assessment of 2D/3D Registration Accuracy in 4 Major Anatomic Sites Using On-Board 2D Kilovoltage Images for 6D Patient Setup.

Authors:  Guang Li; T Jonathan Yang; Hugo Furtado; Wolfgang Birkfellner; Åse Ballangrud; Simon N Powell; James Mechalakos
Journal:  Technol Cancer Res Treat       Date:  2014-09-15

Review 7.  Computed tomography imaging superimposition protocols to assess outcomes in orthognathic surgery: a systematic review with comprehensive recommendations.

Authors:  Fernando de Oliveira Andriola; Orion Luiz Haas Junior; Raquel Guijarro-Martínez; Federico Hernández-Alfaro; Rogério Belle de Oliveira; Rogério Miranda Pagnoncelli; Gwen Rj Swennen
Journal:  Dentomaxillofac Radiol       Date:  2021-09-14       Impact factor: 2.419

8.  Correction of motion-induced misalignment in co-registered PET/CT and MRI (T1/T2/FLAIR) head images for stereotactic radiosurgery.

Authors:  Guang Li; Huchen Xie; Holly Ning; Deborah Citrin; Aradhana Kaushal; Kevin Camphausen; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2010-10-07       Impact factor: 2.102

9.  Accuracy of 3D volumetric image registration based on CT, MR and PET/CT phantom experiments.

Authors:  Guang Li; Huchen Xie; Holly Ning; Deborah Citrin; Jacek Capala; Roberto Maass-Moreno; Peter Guion; Barbara Arora; Norman Coleman; Kevin Camphausen; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2008-07-09       Impact factor: 2.102

10.  Enhanced super-resolution reconstruction of T1w time-resolved 4DMRI in low-contrast tissue using 2-step hybrid deformable image registration.

Authors:  Xingyu Nie; Kirk Huang; Joseph Deasy; Andreas Rimner; Guang Li
Journal:  J Appl Clin Med Phys       Date:  2020-09-22       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.