Literature DB >> 16022982

A new approach for the Martell 3-D method of measuring polyethylene wear without requiring the cross-table lateral films.

Charles R Bragdon1, John M Martell, Daniel M Estok, Meridith E Greene, Henrik Malchau, William H Harris.   

Abstract

Due to the uneven and often inadequate quality of cross-table lateral hip radiographs, many radiographic studies of femoral head penetration into polyethylene in total hip arthroplasty are limited to the two-dimensional measurement of femoral head penetration using the A/P film only. We postulated that the use of two oblique frontal projections at 90 degrees to each other would improve the three-dimensional evaluation. Using an established hip phantom, the idealized accuracy and precision of the three-dimensional Martell method was evaluated, contrasting the standard A/P and cross-table lateral projections versus a pair of oblique projections by four independent readers. Accuracy and precision resulting from the use of two oblique projections (average accuracy +/-63 microm, precision +/-26 microm) were similar to that obtained using the conventional A/P and cross-table lateral views (accuracy +/-54 microm, precision +/-22 microm), though the results of the two oblique views were slightly more variable. These observations suggest that by using two oblique A/P projections, the major disadvantage of using the cross-table lateral films, namely the variable quality of the images, is avoided. Perhaps, therefore, the utility and availability of three-dimensional data in comparable clinical studies may be improved.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16022982     DOI: 10.1016/j.orthres.2004.07.008

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.

Authors:  Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2016-11-04       Impact factor: 3.075

Review 2.  What are the current clinical issues in wear and tribocorrosion?

Authors:  Daniel J Berry; Matthew P Abdel; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

3.  Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique.

Authors:  Eric Vandenbussche; Mohammed Saffarini; Ulrich Hansen; Fabienne Taillieu; Céline Mutschler; Bernard Augereau; Thomas M Gregory
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

4.  A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty.

Authors:  G N Solayar; J Chinappa; I A Harris; D B Chen; S J Macdessi
Journal:  Malays Orthop J       Date:  2017-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.