OBJECTIVES: This study validates the off-pump antegrade transventricular route for ultrasound-guided direct-access aortic valved stent implantation. BACKGROUND: Direct-access aortic valved stent implantation offers numerous advantages over the remote-access percutaneous approach and may one day provide an alternative to surgical aortic valve replacement. METHODS: Valved stents were implanted off-pump in 12 pigs (68.5.0 +/- 7.3 kg) via direct-access transapical approach using a left-sided mini-thoracotomy and continuous ultrasonic and fluoroscopic guidance. Acute valved stent function was studied with intravascular and intracardiac ultrasound. All valved stents were tested in vitro before insertion. Macroscopic analysis was performed at necropsy. RESULTS: In 8 of 12 pigs, valved stents were delivered to the target site over the native aortic valve leaflets without interference of coronary blood flow and with good acute valve function. Two valved stents were deployed and supra-annularly occluded the coronary orifice, leading to fatal outcome. Two valved stents dislodged into the left ventricle, one because of size mismatch and one that failed to unfold correctly. CONCLUSIONS: Twelve pigs underwent deployment of a valved stent in the aortic position. Six valves observed for an average 4.5-h period showed satisfactory postimplantation valve function.
OBJECTIVES: This study validates the off-pump antegrade transventricular route for ultrasound-guided direct-access aortic valved stent implantation. BACKGROUND: Direct-access aortic valved stent implantation offers numerous advantages over the remote-access percutaneous approach and may one day provide an alternative to surgical aortic valve replacement. METHODS: Valved stents were implanted off-pump in 12 pigs (68.5.0 +/- 7.3 kg) via direct-access transapical approach using a left-sided mini-thoracotomy and continuous ultrasonic and fluoroscopic guidance. Acute valved stent function was studied with intravascular and intracardiac ultrasound. All valved stents were tested in vitro before insertion. Macroscopic analysis was performed at necropsy. RESULTS: In 8 of 12 pigs, valved stents were delivered to the target site over the native aortic valve leaflets without interference of coronary blood flow and with good acute valve function. Two valved stents were deployed and supra-annularly occluded the coronary orifice, leading to fatal outcome. Two valved stents dislodged into the left ventricle, one because of size mismatch and one that failed to unfold correctly. CONCLUSIONS: Twelve pigs underwent deployment of a valved stent in the aortic position. Six valves observed for an average 4.5-h period showed satisfactory postimplantation valve function.
Authors: Johan van der Merwe; Filip Casselman; Bernard Stockman; Frank Van Praet; Roel Beelen; Lieven Maene; Yvette Vermeulen; Ivan Degrieck Journal: Ann Cardiothorac Surg Date: 2015-03
Authors: Keith A Horvath; Dumitru Mazilu; Michael Guttman; Arthur Zetts; Timothy Hunt; Ming Li Journal: J Thorac Cardiovasc Surg Date: 2009-12-06 Impact factor: 5.209
Authors: Miriam Weisskopf; Lukas Glaus; Nina E Trimmel; Melanie M Hierweger; Andrea S Leuthardt; Marian Kukucka; Thorald Stolte; Christian T Stoeck; Volkmar Falk; Maximilian Y Emmert; Markus Kofler; Nikola Cesarovic Journal: Front Vet Sci Date: 2022-09-02
Authors: Gabor Erdoes; Christoph Huber; Reto Basciani; Stefan Stortecky; Stephan Windecker; Peter Wenaweser; Thierry Carrel; Balthasar Eberle Journal: PLoS One Date: 2014-10-07 Impact factor: 3.240