Literature DB >> 16022969

Direct-access valve replacement a novel approach for off-pump valve implantation using valved stents.

Christoph H Huber1, Lawrence H Cohn, Ludwig K von Segesser.   

Abstract

OBJECTIVES: This study validates the off-pump antegrade transventricular route for ultrasound-guided direct-access aortic valved stent implantation.
BACKGROUND: Direct-access aortic valved stent implantation offers numerous advantages over the remote-access percutaneous approach and may one day provide an alternative to surgical aortic valve replacement.
METHODS: Valved stents were implanted off-pump in 12 pigs (68.5.0 +/- 7.3 kg) via direct-access transapical approach using a left-sided mini-thoracotomy and continuous ultrasonic and fluoroscopic guidance. Acute valved stent function was studied with intravascular and intracardiac ultrasound. All valved stents were tested in vitro before insertion. Macroscopic analysis was performed at necropsy.
RESULTS: In 8 of 12 pigs, valved stents were delivered to the target site over the native aortic valve leaflets without interference of coronary blood flow and with good acute valve function. Two valved stents were deployed and supra-annularly occluded the coronary orifice, leading to fatal outcome. Two valved stents dislodged into the left ventricle, one because of size mismatch and one that failed to unfold correctly.
CONCLUSIONS: Twelve pigs underwent deployment of a valved stent in the aortic position. Six valves observed for an average 4.5-h period showed satisfactory postimplantation valve function.

Entities:  

Mesh:

Year:  2005        PMID: 16022969     DOI: 10.1016/j.jacc.2005.04.028

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  9 in total

1.  Transapical aortic valve replacement under real-time magnetic resonance imaging guidance: experimental results with balloon-expandable and self-expanding stents.

Authors:  Keith A Horvath; Dumitru Mazilu; Ozgur Kocaturk; Ming Li
Journal:  Eur J Cardiothorac Surg       Date:  2010-10-22       Impact factor: 4.191

2.  Transapical access closure: the TA PLUG device.

Authors:  Henriette Brinks; Fabian Nietlispach; Volkhard Göber; Lars Englberger; Peter Wenaweser; Bernhard Meier; Thierry Carrel; Christoph Huber
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-07-09

3.  Self-Expanding Stent and Delivery System for Aortic Valve Replacement.

Authors:  Dumitru Mazilu; Ming Li; Ozgur Kocaturk; Keith A Horvath
Journal:  J Med Device       Date:  2012-11-01       Impact factor: 0.582

4.  Minimally invasive primary aortic valve surgery: the OLV Aalst experience.

Authors:  Johan van der Merwe; Filip Casselman; Bernard Stockman; Frank Van Praet; Roel Beelen; Lieven Maene; Yvette Vermeulen; Ivan Degrieck
Journal:  Ann Cardiothorac Surg       Date:  2015-03

5.  Midterm results of transapical aortic valve replacement via real-time magnetic resonance imaging guidance.

Authors:  Keith A Horvath; Dumitru Mazilu; Michael Guttman; Arthur Zetts; Timothy Hunt; Ming Li
Journal:  J Thorac Cardiovasc Surg       Date:  2009-12-06       Impact factor: 5.209

6.  Percutaneous interventricular septal access in a patient with aortic and mitral mechanical valves: a novel technique for catheter ablation of ventricular tachycardia.

Authors:  Marmar Vaseghi; Carlos Macias; Roderick Tung; Kalyanam Shivkumar
Journal:  Heart Rhythm       Date:  2013-04-30       Impact factor: 6.343

7.  Dos and don'ts in large animal models of aortic insufficiency.

Authors:  Miriam Weisskopf; Lukas Glaus; Nina E Trimmel; Melanie M Hierweger; Andrea S Leuthardt; Marian Kukucka; Thorald Stolte; Christian T Stoeck; Volkmar Falk; Maximilian Y Emmert; Markus Kofler; Nikola Cesarovic
Journal:  Front Vet Sci       Date:  2022-09-02

8.  Minimally invasive cardiac surgery: transapical aortic valve replacement.

Authors:  Ming Li; Dumitru Mazilu; Keith A Horvath
Journal:  Minim Invasive Surg       Date:  2012-10-16

9.  The self-expanding Symetis Acurate does not increase cerebral microembolic load when compared to the balloon-expandable Edwards Sapien prosthesis: a transcranial Doppler study in patients undergoing transapical aortic valve implantation.

Authors:  Gabor Erdoes; Christoph Huber; Reto Basciani; Stefan Stortecky; Stephan Windecker; Peter Wenaweser; Thierry Carrel; Balthasar Eberle
Journal:  PLoS One       Date:  2014-10-07       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.