Literature DB >> 16015157

Neural response telemetry results with the nucleus 24 contour in a perimodiolar position.

Michael D Seidman1, Prashant Vivek, William Dickinson.   

Abstract

OBJECTIVE: The purpose of the study was to analyze changes in neural response telemetry using the Cochlear Nucleus 24 Contour before and after stylet removal in a human model. STUDY
DESIGN: Prospective study.
SETTING: Tertiary referral center. PATIENTS: Twelve patients (23-72 years old) undergoing cochlear implantation, using the Nucleus 24 Contour implant, secondary to congenital and age-related hearing loss. INTERVENTION: Cochlear implantation with Cochlear Nucleus 24 Contour implant. MAIN OUTCOME MEASURE: Neural response telemetry thresholds were recorded initially with the stylet in and then with the stylet out during the implant procedure.
RESULTS: Stimulus levels to obtain neural response telemetry threshold after stylet removal were statistically lower after the stylet was removed.
CONCLUSION: The Nucleus 24 Contour achieves a perimodiolar position once the stylet is removed, and this leads to reduction in the current required to elicit a threshold neural response telemetry response.

Entities:  

Mesh:

Year:  2005        PMID: 16015157     DOI: 10.1097/01.mao.0000178122.35988.df

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  7 in total

1.  Intra-Operative Neural Response Telemetry and Acoustic Reflex Assessment using an Advance-In-Stylet Technique and Modiolus-Hugging: A prospective cohort study.

Authors:  Abdulrahman Hagr
Journal:  Sultan Qaboos Univ Med J       Date:  2011-08-15

2.  Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study.

Authors:  Philipp Mittmann; I Todt; A Ernst; G Rademacher; S Mutze; S Göricke; M Schlamann; R Ramalingam; S Lang; F Christov; D Arweiler-Harbeck
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-06-28       Impact factor: 2.503

3.  Insertion trauma of a cochlear implant electrode array with Nitinol inlay.

Authors:  Thomas S Rau; Lenka Harbach; Nick Pawsey; Marcel Kluge; Peter Erfurt; Thomas Lenarz; Omid Majdani
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-03-09       Impact factor: 2.503

4.  Cochlear implantation with the nucleus slim modiolar electrode (CI532): a preliminary experience.

Authors:  Domenico Cuda; Alessandra Murri
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-10-14       Impact factor: 2.503

5.  Comparative study of two different perimodiolar and a straight cochlear implant electrode array: surgical and audiological outcomes.

Authors:  Octavio Garaycochea; Raquel Manrique-Huarte; Carlos Lazaro; Alicia Huarte; Carlos Prieto; Marta Alvarez de Linera-Alperi; Manuel Manrique
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-10-21       Impact factor: 2.503

6.  Assessment of cochlear trauma and telemetry measures after cochlear implantation: A comparative study between Nucleus® CI512 and CI532 electrode arrays.

Authors:  Domenico Cuda; Alessandra Murri
Journal:  Audiol Res       Date:  2019-07-11

7.  Advances to electrode pullback in cochlear implant surgery.

Authors:  Ingo Todt; Dietmar Basta; Rainer Seidl; Arne Ernst
Journal:  ScientificWorldJournal       Date:  2012-10-22
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.