Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications.

Emily Poon1, Frank Verhaegen.   

Abstract

This work involves a validation of the photon and electron transport of the GEANT4 particle simulation toolkit for radiotherapy physics applications. We examine the cross sections and sampling algorithms of the three electromagnetic physics models in version 4.6.1 of the toolkit: Standard, Low-energy, and Penelope. The depth dose distributions in water for incident monoenergetic and clinical beams are compared to the EGSNRC results. In photon beam simulations, all three models agree with EGSNRC to within 2%, except for the buildup region. Larger deviations are found for incident electron beams, and the differences are affected by user-imposed electron step limitations. Particle distributions through thin layers of clinical target materials, and perturbation effects near high-Z and low-Z interfaces are also investigated. The electron step size artifacts observed in our studies indicate potential problems with the condensed history algorithm. A careful selection of physics processes and transport parameters is needed for optimum efficiency and accuracy.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16013728     DOI: 10.1118/1.1895796

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Monte Carlo simulation of large electron fields.

Authors:  Bruce A Faddegon; Joseph Perl; Makoto Asai
Journal:  Phys Med Biol       Date:  2008-02-21       Impact factor: 3.609

2.  A model of cellular dosimetry for macroscopic tumors in radiopharmaceutical therapy.

Authors:  Robert F Hobbs; Sébastien Baechler; De-Xue Fu; Caroline Esaias; Martin G Pomper; Richard F Ambinder; George Sgouros
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

3.  Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4.

Authors:  Hiroyuki Okamoto; Yukio Fujita; Kyoko Sakama; Hidetoshi Saitoh; Tatsuaki Kanai; Jun Itami; Toshiyuki Kohno
Journal:  Radiol Phys Technol       Date:  2014-02-08

4.  The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras.

Authors:  Dennis Mackin; Jerimy Polf; Steve Peterson; Sam Beddar
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy.

Authors:  Bruce A Faddegon; Iwan Kawrakow; Yuri Kubyshin; Joseph Perl; Josep Sempau; Laszlo Urban
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

Review 6.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

7.  Simulation of the 6 MV Elekta Synergy Platform linac photon beam using Geant4 Application for Tomographic Emission.

Authors:  Samir Didi; Abdelilah Moussa; Tayalati Yahya; Zerfaoui Mustafa
Journal:  J Med Phys       Date:  2015 Jul-Sep

8.  A Comparison Between GATE and MCNPX Monte Carlo Codes in Simulation of Medical Linear Accelerator.

Authors:  Hamid-Reza Sadoughi; Shahrokh Nasseri; Mahdi Momennezhad; Hamid-Reza Sadeghi; Mohammad-Hossein Bahreyni-Toosi
Journal:  J Med Signals Sens       Date:  2014-01
  8 in total