Compton-scattering measurement of diagnostic x-ray spectrum using high-resolution Schottky CdTe detector.

Koji Maeda1, Masao Matsumoto, Akira Taniguchi.   

Abstract

The analysis of x-ray spectra is important for quality assurance (QA) and quality control (QC) of radiographic systems. The aim of this study is to measure the diagnostic x-ray spectra under clinical conditions using a high-resolution Schottky CdTe detector. Under clinical conditions, the direct measurement of a diagnostic spectrum is difficult because of the high photon fluence rates that cause significant detector photon pile-up. An alternative way of measuring the output spectra from a tube is first to measure the 90 deg Compton scattered photons from a given sample. With this set-up detector, pile-up is not a problem. From the scattered spectrum one can then use an energy correction and the Klein-Nishina function to reconstruct the actual spectrum incident upon the scattering sample. The verification of whether our spectra measured by the Compton method are accurate was accomplished by comparing exposure rates calculated from the reconstructed spectra to those measured with an ionization chamber. We used aluminum (Al) filtration ranging in thickness from 0 to 6 mm. The half value layers (HVLs) obtained for a 70 kV beam were 2.78 mm via the ionization chamber measurements and 2.93 mm via the spectral measurements. For a 100 kV beam we obtained 3.98 and 4.32 mm. The small differences in HVLs obtained by both techniques suggest that Compton scatter spectroscopy with a Schottky CdTe detector is suitable for measuring the diagnostic x-ray spectra and useful for QA and QC of clinical x-ray equipment.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16013712     DOI: 10.1118/1.1921647

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography.

Authors:  D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

2.  Segmentation-free x-ray energy spectrum estimation for computed tomography using dual-energy material decomposition.

Authors:  Wei Zhao; Lei Xing; Qiude Zhang; Qingguo Xie; Tianye Niu
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-30

3.  Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.

Authors:  Francois Lessard; Louis Archambault; Mathieu Plamondon; Philippe Despres; Franccois Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

4.  Practical method for determination of air kerma by use of an ionization chamber toward construction of a secondary X-ray field to be used in clinical examination rooms.

Authors:  Itsumi Maehata; Hiroaki Hayashi; Natsumi Kimoto; Kazuki Takegami; Hiroki Okino; Yuki Kanazawa; Masahide Tominaga
Journal:  Radiol Phys Technol       Date:  2016-03-18

5.  Semiempirical, parameterized spectrum estimation for x-ray computed tomography.

Authors:  Paul FitzGerald; Stephen Araujo; Mingye Wu; Bruno De Man
Journal:  Med Phys       Date:  2021-03-16       Impact factor: 4.071

6.  The impact of spectral filtration on image quality in micro-CT system.

Authors:  Liqiang Ren; Muhammad U Ghani; Di Wu; Bin Zheng; Yong Chen; Kai Yang; Xizeng Wu; Hong Liu
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

7.  Development of a denoising convolutional neural network-based algorithm for metal artifact reduction in digital tomosynthesis for arthroplasty: A phantom study.

Authors:  Tsutomu Gomi; Rina Sakai; Hidetake Hara; Yusuke Watanabe; Shinya Mizukami
Journal:  PLoS One       Date:  2019-09-13       Impact factor: 3.240

Review 8.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.