Optimal dose of Gd-DTPA in dynamic MR studies.

H Rusinek1, V S Lee, G Johnson.   

Abstract

The relationship between the administered dose d of Gd-DTPA and the accuracy of measurements of the glomerular filtration rate G and the cardiac output O was investigated. For a wide range of values the concentration of Gd-DTPA can be uniquely derived from MR signals and precontrast longitudinal relaxation time. Fixed and random errors in these measured variables were analyzed. Depending on noise level and the level of renal function, errors in G reach a minimum for d = 1.4-2.8 mmol. Random errors in G are relatively insensitive to d as long as d > 1.5 mmol. These results establish the feasibility of dynamic MR measurements using doses of Gd-DTPA that are several times lower than current standards.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11477635     DOI: 10.1002/mrm.1193

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Three-dimensional isotropic contrast-enhanced MR angiography of the carotid artery using sensitivity-encoding and random elliptic centric k-space filling: technique optimization.

Authors:  G Riedy; X Golay; E R Melhem
Journal:  Neuroradiology       Date:  2005-07-13       Impact factor: 2.804

Review 2.  MR urography in children.

Authors:  J Damien Grattan-Smith; Richard A Jones
Journal:  Pediatr Radiol       Date:  2006-06-22

Review 3.  Renal relevant radiology: renal functional magnetic resonance imaging.

Authors:  Behzad Ebrahimi; Stephen C Textor; Lilach O Lerman
Journal:  Clin J Am Soc Nephrol       Date:  2013-12-26       Impact factor: 8.237

4.  Contrast-enhanced dynamic MR nephrography using the TurboFLASH navigator-gating technique in children.

Authors:  Andreas Boss; Juergen F Schaefer; Petros Martirosian; Hans-Walter Hacker; Kassa Darge; Claus D Claussen; Klaus Küper; Fritz Schick; Heinz-Peter Schlemmer
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

5.  Gadoxetate-enhanced MR imaging and compartmental modelling to assess hepatocyte bidirectional transport function in rats with advanced liver fibrosis.

Authors:  Céline Giraudeau; Benjamin Leporq; Sabrina Doblas; Matthieu Lagadec; Catherine M Pastor; Jean-Luc Daire; Bernard E Van Beers
Journal:  Eur Radiol       Date:  2016-08-23       Impact factor: 5.315

6.  Assessment of liver function in primary biliary cirrhosis using Gd-EOB-DTPA-enhanced liver MRI.

Authors:  Henrik Nilsson; Lennart Blomqvist; Lena Douglas; Anders Nordell; Eduard Jonas
Journal:  HPB (Oxford)       Date:  2010-10       Impact factor: 3.647

7.  Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis.

Authors:  Pierre-Hugues Vivier; Pippa Storey; Henry Rusinek; Jeff L Zhang; Akira Yamamoto; Kristopher Tantillo; Umer Khan; Ruth P Lim; James S Babb; Devon John; Lewis W Teperman; Hersh Chandarana; Kent Friedman; Judith A Benstein; Edward Y Skolnik; Vivian S Lee
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

8.  Optimization of saturation-recovery dynamic contrast-enhanced MRI acquisition protocol: monte carlo simulation approach demonstrated with gadolinium MR renography.

Authors:  Jeff L Zhang; Chris C Conlin; Kristi Carlston; Luke Xie; Daniel Kim; Glen Morrell; Kathryn Morton; Vivian S Lee
Journal:  NMR Biomed       Date:  2016-05-20       Impact factor: 4.044

Review 9.  Assessment of renal function with dynamic contrast-enhanced MR imaging.

Authors:  Louisa Bokacheva; Henry Rusinek; Jeff L Zhang; Vivian S Lee
Journal:  Magn Reson Imaging Clin N Am       Date:  2008-11       Impact factor: 2.266

  9 in total