Pulse pressure vs. total arterial compliance as a marker of arterial health.

B A Haluska1, L Jeffriess, R B Fathi, P M Mottram, S G Carlier, T H Marwick.   

Abstract

BACKGROUND: Brachial pulse pressure (BPP) is a predictor of outcome in epidemiologic studies, but brachial and aortic pulse pressure (AoPP) may not correspond and both are influenced by multiple parameters including arterial properties and cardiac output. We sought to what extent pulse pressure (PP) measurements reflected direct measurement of arterial properties, assessed as total arterial compliance (TAC).
METHODS: We studied 123 patients (76 men; age 55 +/- 11); 31 normal controls, 46 patients with coronary artery disease and 46 patients with hypertension. PP was determined from brachial cuff pressure and TAC was measured by simultaneous radial applanation tonometry and pulsed wave Doppler of the LV outflow. AoPP was calculated using a transfer function from the radial waveform.
RESULTS: There was a significant difference between BPP and AoPP (57 +/- 16 vs. 45 +/- 14; P < 0.0001), although TAC correlated with BPP (r = -0.72; P = 0.01) and AoPP (r = -0.66; P = 0.01). In a multiple linear regression, the difference between BPP and AoPP was predicted by cardiac output (CO) (P = 0.002) and gender (P = 0.03). Bland-Altman analysis showed the best correspondence between BPP and AoPP in the middle tertile (CO 4.7 to 5.7 L min(-1)) with less correlation in the low and high tertiles. The same analysis by gender showed a higher difference in women than men (14 +/- 6 vs. 10 +/- 5; P < 0.0001). The difference between BPP and AoPP showed the best correlation in the control group and the worst in the hypertension group.
CONCLUSION: BPP correlates with TAC in men with normal cardiac function. However, in women, in patients at the low and high extremes of function, and in patients with preclinical and overt cardiovascular disease, there appears to be incremental value in measuring TAC.

Entities:  

Mesh:

Year:  2005        PMID: 16008545     DOI: 10.1111/j.1365-2362.2005.01513.x

Source DB:  PubMed          Journal:  Eur J Clin Invest        ISSN: 0014-2972            Impact factor:   4.686


  4 in total

Review 1.  Accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.

Authors:  Haitao Chu; Yong Wang; Yanfei Sun; Gang Wang
Journal:  J Clin Monit Comput       Date:  2015-08-05       Impact factor: 2.502

2.  Impaired left ventricular stroke volume reserve during clinical dobutamine stress predicts future episodes of pulmonary edema.

Authors:  Charaslak Charoenpanichkit; William C Little; Sangeeta Mandapaka; Erica Dall'Armellina; Timothy M Morgan; Craig A Hamilton; W Gregory Hundley
Journal:  J Am Coll Cardiol       Date:  2011-02-15       Impact factor: 24.094

3.  Influence of beat-to-beat blood pressure variability on vascular elasticity in hypertensive population.

Authors:  Yufa Xia; Xin Liu; Dan Wu; Huahua Xiong; Lijie Ren; Lin Xu; Wanqing Wu; Heye Zhang
Journal:  Sci Rep       Date:  2017-08-21       Impact factor: 4.379

4.  Association between beat-to-beat blood pressure variability and vascular elasticity in normal young adults during the cold pressor test.

Authors:  Yufa Xia; Dan Wu; Zhifan Gao; Xin Liu; Qian Chen; Lijie Ren; Wanqing Wu
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.