| Literature DB >> 28225488 |
Yufa Xia1, Dan Wu, Zhifan Gao, Xin Liu, Qian Chen, Lijie Ren, Wanqing Wu.
Abstract
The beat-to-beat blood pressure (BP) monitoring parameters, such as average beat-to-beat BP, BP variability (BPV), could have an influence on the vascular elasticity. This study hypothesized that the elevated beat-to-beat BPV could evoke the reduction of the vascular elasticity independent of BP levels. We measured the beat-to-beat BP recordings and total arterial compliance (TAC), which was used to assess the vascular elasticity, in 80 young healthy adults during the cold pressor test (CPT). The CPT included 3 phases: baseline phase, cold stimulus phase, recovery phase. Six parameters were used to estimate BPV. In bivariate correlation analysis, TAC showed a significant correlation with systolic BP (SBP) and diastolic BP (DBP) in the cold stimulus phase; and 4 indices of SBP variability (SBPV) were associated with TAC (r = 0.271∼0.331, P ≤ 0.015) in the recovery phase; similarly, 2 indices of DBP variability (DBPV) were also correlated with TAC (r = 0.221∼0.285, P ≤ 0.048) in the recovery phase. In multivariate regression analysis, DBPV (β = 0.229, P = 0.001) was a determinant of TAC independent of average DBP, sex, and weight. In addition, both beat-to-beat BP and BPV values increased in the cold stimulus phase (P < 0.01); whereas, the TAC decreased in the cold stimulus phase (P < 0.01). In conclusion, these data suggest that the beat-to-beat DBPV shows an independent association with the vascular elasticity in young normal adults during the CPT.Entities:
Mesh:
Year: 2017 PMID: 28225488 PMCID: PMC5348138 DOI: 10.1097/MD.0000000000006000
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.817
Figure 1The 3 phases of the cold pressor test.
Clinical characteristics of the study subjects.
The beat-to-beat blood pressure parameters, heart rate parameters, and total arterial compliance in 3 phases of cold pressor test.
Pearson correlation of total arterial compliance with demographic data, heart rate, beat-to-beat blood pressure parameters.
Independent predictors of total arterial compliance in multivariate linear regression analysis during cold stimulus phase of cold pressor test.
Independent predictors of total arterial compliance in multivariate linear regression analysis during recovery phase of cold pressor test.
Figure 2The linear relationship between TAC and VIM of DBP in the recovery phase of CPT. CPT = cold pressor test, DBP = diastolic blood pressure, TAC = total arterial compliance, VIM = variation independent of mean.