Literature DB >> 16005794

Effect of smear layer thickness and acidity of self-etching solutions on early and long-term bond strength to dentin.

Alessandra Reis1, Viviane Grandi, Larissa Carlotto, Giana Bortoli, Rafael Patzlaff, Maria de Lourdes Rodrigues Accorinte, Alessandro Dourado Loguercio.   

Abstract

OBJECTIVES: To evaluate the effect of smear layer thickness (SL) on early and 6-month bond strength (BS) of self-etching adhesives to dentin and to measure the ultimate microtensile strength (UTS) of the adhesives.
METHODS: Clearfil SE Bond; Optibond Solo Plus Self-Etch Primer; Tyrian Self Priming Etchant (TY) and as controls, Single Bond (SB) and Scotchbond Multi-Purpose Plus (SBMP) were applied on flat superficial dentin surface with thick and thin SL thicknesses. After adhesive's application (n=6) a resin build-up was made. After 24h, resin-dentin beams (0.8mm(2)) were prepared to be tested immediately and after 6-month (6M) at 0.5mm/min. For the UTS measurement, hour-glass specimens were prepared with the bonding resin alone or after mixing (1:1). BS values were analyzed by three-way repeated measures ANOVA and Tukey's multiple comparison tests. Two-way ANOVA (bonding resin and bonding resin+self-etching primer) and Tukey's test were used for the UTS values. The bonding resins were re-evaluated separately by a one-way ANOVA and Tukey's test, since Single Bond is a one-bottle adhesive (alpha=0.05).
RESULTS: The SL thickness was not significant (p=0.64). BS values were reduced after 6M, except for the SBMP. TY provided the lowest BS mean while SB and SBMP the highest BS. The UTS of the SBMP was the highest. TY yielded the lowest UTS. Regression analysis revealed a linear and significant relationship between the UTS of self-etch systems and the mean BS (R=0.95, p=0.02).
CONCLUSIONS: The performance of a self-etching system does not seem to be dependent on the SL thickness. The total-etch, three-step system provided the highest BS to dentin and maintained the BS stable over 6 months. The performance of the self-etching systems can be envisaged by their UTS.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16005794     DOI: 10.1016/j.jdent.2004.12.003

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  19 in total

1.  24-month clinical evaluation in non-carious cervical lesions of a two-step etch-and-rinse adhesive applied using a rubbing motion.

Authors:  Alessandro D Loguercio; Jovani Raffo; Fabrício Bassani; Heloiza Balestrini; Dalvan Santo; Roberto César do Amaral; Alessandra Reis
Journal:  Clin Oral Investig       Date:  2010-04-20       Impact factor: 3.573

2.  Plasma treatment of dentin surfaces for improving self-etching adhesive/dentin interface bonding.

Authors:  Xiaoqing Dong; Hao Li; Meng Chen; Yong Wang; Qingsong Yu
Journal:  Clin Plasma Med       Date:  2015-06-01

3.  Morphology of the smear layer after the application of simplified self-etch adhesives on enamel and dentin surfaces created with different preparation methods.

Authors:  Tissiana Bortolotto; Marco Ferrari; Alexandre Susin; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2009-01-09       Impact factor: 3.573

Review 4.  Classification review of dental adhesive systems: from the IV generation to the universal type.

Authors:  Eshrak Sofan; Afrah Sofan; Gaspare Palaia; Gianluca Tenore; Umberto Romeo; Guido Migliau
Journal:  Ann Stomatol (Roma)       Date:  2017-07-03

5.  Influence of dentin and enamel pretreatment with acidic sulfur compounds on adhesive performance.

Authors:  Alexis Ioannidis; Bogna Stawarczyk; Beatrice Sener; Thomas Attin; Patrick R Schmidlin
Journal:  Clin Oral Investig       Date:  2012-11-09       Impact factor: 3.573

6.  Transdentinal cytotoxicity of resin-based luting cements to pulp cells.

Authors:  Lucas da Fonseca Roberti Garcia; Elaine Cristina Voltolini Pontes; Fernanda Gonçalves Basso; Josimeri Hebling; Carlos Alberto de Souza Costa; Diana Gabriela Soares
Journal:  Clin Oral Investig       Date:  2015-10-19       Impact factor: 3.573

7.  Three-year clinical evaluation of a two-step self-etch adhesive with or without selective enamel etching in non-carious cervical sclerotic lesions.

Authors:  Esra Can Say; Emre Özel; Haktan Yurdagüven; Mübin Soyman
Journal:  Clin Oral Investig       Date:  2013-11-22       Impact factor: 3.573

Review 8.  Validity of bond strength tests: A critical review-Part II.

Authors:  Kantheti Sirisha; Tankonda Rambabu; Yalavarthi Ravishankar; Pabbati Ravikumar
Journal:  J Conserv Dent       Date:  2014-09

9.  Bond strength and morphology of enamel using self-etching adhesive systems with different acidities.

Authors:  Sandra Kiss Moura; Alessandra Reis; Arlete Pelizzaro; Karen Dal-Bianco; Alessandro Dourado Loguercio; Victor Elias Arana-Chavez; Rosa Helena Miranda Grande
Journal:  J Appl Oral Sci       Date:  2009 Jul-Aug       Impact factor: 2.698

10.  The influence of air temperature for solvent evaporation on bonding of self-etch adhesives to dentin.

Authors:  Sandra Kiss Moura; Cintia Gaio Murad; Alessandra Reis; Celso Afonso Klein-Júnior; Rosa Helena Miranda Grande; Alessandro Dourado Loguercio
Journal:  Eur J Dent       Date:  2014-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.