Literature DB >> 16000666

Endoscopic reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws: a prospective randomized study of the clinical outcome.

Jon Olav Drogset1, Torbjørn Grøntvedt, Agnar Tegnander.   

Abstract

BACKGROUND: During the past decade, bioabsorbable interference screws have become increasingly popular in endoscopic reconstructions of the anterior cruciate ligament. With these screws, there is no need for a second operation for removal and no complicating factor if later revision surgery is necessary. Several pullout studies have found similar results between metal and bioabsorbable interference screws; however, few studies have investigated the clinical outcome. HYPOTHESIS: There is no difference in the clinical outcome of bioabsorbable interference screws compared with metal screws. STUDY
DESIGN: Randomized controlled clinical trial; Level of evidence, 1.
METHODS: Forty-one patients were randomized for the use of either metal interference screws (20 patients) or bioabsorbable poly-l-lactic acid screws (21 patients). The patients were followed with clinical examinations at 6, 12, and 24 weeks and at 1 and 2 years postoperatively.
RESULTS: Subjective knee function was better in the patients in the metal screw group; they had less pain at rest, a higher Tegner score, a higher Lysholm score, and better subjective knee function at 2 years compared to the bioabsorbable screw group. However, there was no difference in stability between the groups. CONCLUSION AND CLINICAL RELEVANCE: Because of the inferior results in the bioabsorbable screw group in our study, and until larger studies show otherwise, we do not find the advantages of using bioabsorbable screws sufficient to warrant the routine use of poly-L-lactic acid screws in anterior cruciate ligament reconstructions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16000666     DOI: 10.1177/0363546504272264

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  18 in total

1.  CALAXO osteoconductive interference screw: the value of postmarket surveillance.

Authors:  Charles L Cox; Kelly C Homlar; James L Carey; Kurt P Spindler
Journal:  J Surg Orthop Adv       Date:  2010

2.  Autologous patellar tendon and quadrupled hamstring grafts in anterior cruciate ligament reconstruction: a prospective randomized multicenter review of different fixation methods.

Authors:  Jon Olav Drogset; Torbjørn Strand; Gisle Uppheim; Bjørn Odegård; Asbjørn Bøe; Torbjørn Grøntvedt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-12-03       Impact factor: 4.342

Review 3.  Variables associated with return to sport following anterior cruciate ligament reconstruction: a systematic review.

Authors:  Sylvia Czuppon; Brad A Racette; Sandra E Klein; Marcie Harris-Hayes
Journal:  Br J Sports Med       Date:  2013-10-11       Impact factor: 13.800

4.  Meta-analysis comparing bioabsorbable versus metal interference screw for adverse and clinical outcomes in anterior cruciate ligament reconstruction.

Authors:  Pat Laupattarakasem; Malinee Laopaiboon; Weerachai Kosuwon; Wiroon Laupattarakasem
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-14       Impact factor: 4.342

5.  Arthroscopic single-bundle ACL reconstruction with modified double-layer bone-patellar tendon-bone allograft.

Authors:  Hui Jun Kang; Yan Ling Su; Hui Jian Cao; Fei Wang; Da Hai Yu; Zhi Min Zheng; Ying Ze Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-10-04       Impact factor: 4.342

6.  Do newer-generation bioabsorbable screws become incorporated into bone at two years after ACL reconstruction with patellar tendon graft?: A cohort study.

Authors:  Charles L Cox; Kurt P Spindler; James P Leonard; Brent J Morris; Warren R Dunn; Emily K Reinke
Journal:  J Bone Joint Surg Am       Date:  2014-02-05       Impact factor: 5.284

Review 7.  Fixation techniques for the anterior cruciate ligament reconstruction: early follow-up. A systematic review of level I and II therapeutic studies.

Authors:  Andrea Speziali; Marco Delcogliano; Matteo Tei; Giacomo Placella; Matteo Bartoli; Amerigo Menghi; Giuliano Cerulli
Journal:  Musculoskelet Surg       Date:  2014-10-01

Review 8.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

9.  Anterior cruciate ligament reconstruction using autografts and double biodegradable femoral cross-pin fixation: functional, radiographic and MRI outcome after 2-year minimum follow-up.

Authors:  Patrick Weninger; Benno Zifko; Michael Liska; Ralf Spitaler; Hartmut Pelinka; Harald Hertz
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-13       Impact factor: 4.342

10.  Intraoperative findings and procedures in culturally and geographically different patient and surgeon populations: an anterior cruciate ligament reconstruction registry comparison between Norway and the USA.

Authors:  Lars-Petter Granan; Maria C S Inacio; Gregory B Maletis; Tadashi T Funahashi; Lars Engebretsen
Journal:  Acta Orthop       Date:  2012-11-01       Impact factor: 3.717