Literature DB >> 15994054

Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking.

Larry W Ehmke1, Daniel C Fitzpatrick, James C Krieg, Steven M Madey, Michael Bottlang.   

Abstract

Previous mechanical studies concerning cut-out of lag screws for pertrochanteric hip fractures have relied on static or dynamic uniaxial loading regimens to induce construct failure by varus collapse and superior cut-out. However, the hip is loaded in a multiplanar, dynamic manner during normal gait. We designed a hip implant performance simulator (HIPS) system to evaluate lag screw cut-out under multiplanar loading representative of normal gait. Five surrogate pertrochanteric fracture specimens with lag screw fixation were loaded up to 20,000 cycles using a biaxial rocking motion (BRM) gait simulation protocol. Another five specimens were loaded using a standard uniaxial loading protocol. The BRM loading group exhibited combined varus collapse (5.4+/-2.9 degrees ) and backward rotation (7.2+/-2.8 degrees ). The uniaxial loading group exhibited four times less varus collapse (1.4+/-1.1 degrees ) as compared to the BRM group, and only negligible rotation. For correlation of lag screw migration in surrogate specimens to that in native bone, six human cadaveric specimens were subjected to BRM loading. The degree of varus collapse (8.5+/-7.7 degrees ) and rotation (7.2+/-6.4 degrees ) in cadaveric specimens were comparable to that in surrogate specimens, with the surrogate specimens showing significantly less variability. The results demonstrate that accounting for clinically realistic multiplanar loading vectors significantly affects implant migration, and therefore should be considered when evaluating the fixation strength of hip screw implants.

Entities:  

Mesh:

Year:  2005        PMID: 15994054     DOI: 10.1016/j.orthres.2005.05.002.1100230614

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  17 in total

1.  Treatment of femoral subtrochanteric fractures with proximal lateral femur locking plates.

Authors:  Sun-Jun Hu; Shi-Min Zhang; Guang-Rong Yu
Journal:  Acta Ortop Bras       Date:  2012-12       Impact factor: 0.513

2.  A unique cause of Gamma 3 cut-out: A case report and literature review.

Authors:  Ioannis Papaioannou; Thomas Repantis; Panagiotis Korovessis
Journal:  J Clin Orthop Trauma       Date:  2020-08-13

Review 3.  Is rotation the mode of failure in pertrochanteric fractures fixed with nails? Theoretical approach and illustrative cases.

Authors:  C Kokoroghiannis; D Vasilakos; K Zisis; G Dimitriou; E Pappa; D Evangelopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-09-20

4.  Clinical outcomes of dynamic hip screw fixation of intertrochanteric fractures: comparison with additional anti-rotation screw use.

Authors:  Chul-Ho Kim; Jae Suk Chang; Ji Wan Kim
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-03-07

5.  Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.

Authors:  Matthias Knobe; Simon Altgassen; Klaus-Jürgen Maier; Gertraud Gradl-Dietsch; Chris Kaczmarek; Sven Nebelung; Kajetan Klos; Bong-Sung Kim; Boyko Gueorguiev; Klemens Horst; Benjamin Buecking
Journal:  Int Orthop       Date:  2017-08-06       Impact factor: 3.075

6.  Evaluation of proximal femoral locking plate in unstable extracapsular proximal femoral fractures: Surgical technique & mid term follow up results.

Authors:  Nishikant Kumar; Himanshu Kataria; Chandrashekhar Yadav; Bharath S Gadagoli; Rishi Raj
Journal:  J Clin Orthop Trauma       Date:  2014-09-10

7.  Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature.

Authors:  Xinning Li; Michael J Heffernan; Christina Kane; Walter Leclair
Journal:  J Orthop Surg Res       Date:  2010-08-27       Impact factor: 2.359

8.  A randomized, prospective study comparing intertrochanteric hip fracture fixation with the dynamic hip screw and the dynamic helical hip system in a community practice.

Authors:  Daniel C Fitzpatrick; Daniel V Sheerin; Brian R Wolf; Thomas K Wuest
Journal:  Iowa Orthop J       Date:  2011

9.  Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation.

Authors:  George K Kouvidis; Mark B Sommers; Peter V Giannoudis; Pavlos G Katonis; Michael Bottlang
Journal:  J Orthop Surg Res       Date:  2009-05-18       Impact factor: 2.359

10.  A review of tip apex distance in dynamic hip screw fixation of osteoporotic hip fractures.

Authors:  Imran Haruna Abdulkareem
Journal:  Niger Med J       Date:  2012-10
View more