Literature DB >> 15988625

Image quality assurance of soft copy display systems.

Emily Seto1, Ali Ursani, Joseph A Cafazzo, Peter G Rossos, Anthony C Easty.   

Abstract

Image quality assurance has traditionally been a high priority in medical imaging departments. Recently, it has often been neglected with the transition from hard copy (film) to soft copy (computer) display systems, which could potentially result in difficulty in reading images or even misdiagnosis. This transition therefore requires careful management such that comparable image quality is achieved at a minimum. It is particularly difficult to maintain appropriate image quality in the clinical settings outside of medical imaging departments because of the volume of display systems and the financial restraints that prohibit the widespread use of dedicated computers and high-quality monitors. In this study, a protocol to test and calibrate display systems was developed and validated by using an inexpensive calibration tool. Using this protocol, monitors were identified in a hospital in which image quality was found to be inadequate for medical image viewing. It was also found that most monitors could achieve a substantial increase in image quality after calibration. For example, the 0 and 5% luminance difference was discernable on 30% of the piloted display systems before calibration, but it was discernable on 100% post calibration. In addition, about 50% of the piloted display systems did not have the maximum luminance (white level) suitably set, and 35% of them did not have the minimum luminance (dark level) suitably set. The results indicate that medical display systems must be carefully selected and strictly monitored, maintained, and calibrated to ensure adequate image quality.

Mesh:

Year:  2005        PMID: 15988625      PMCID: PMC3046728          DOI: 10.1007/s10278-005-6705-0

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  5 in total

1.  Effect of room illuminance on monitor black level luminance and monitor calibration.

Authors:  K Chakrabarti; R V Kaczmarek; J A Thomas; A Romanyukha
Journal:  J Digit Imaging       Date:  2004-01-30       Impact factor: 4.056

2.  Proposal of a quality-index or metric for soft copy display systems: contrast sensitivity study.

Authors:  Jihong Wang; Ken Compton; Qi Peng
Journal:  J Digit Imaging       Date:  2003-09-11       Impact factor: 4.056

3.  An interactive method of assessing the characteristics of softcopy display using observer performance tests.

Authors:  Jihong Wang; Qi Peng
Journal:  J Digit Imaging       Date:  2002-03-19       Impact factor: 4.056

4.  Test pattern for video displays and hard-copy cameras.

Authors:  J E Gray; K G Lisk; D H Haddick; J H Harshbarger; A Oosterhof; R Schwenker
Journal:  Radiology       Date:  1985-02       Impact factor: 11.105

5.  Quality control of cathode-ray tube monitors for medical imaging using a simple photometer.

Authors:  D M Parsons; Y Kim; D R Haynor
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

  5 in total
  1 in total

1.  Medical imaging informatics: how it improves radiology practice today.

Authors:  J Raymond Geis
Journal:  J Digit Imaging       Date:  2007-02-16       Impact factor: 4.056

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.