Impact of multileaf collimator leaf positioning accuracy on intensity modulation radiation therapy quality assurance ion chamber measurements.

M K Woo1, A Nico.   

Abstract

Quality assurance (QA) procedures for intensity modulation radiation therapy (IMRT) usually involve an ion chamber measurement in a phantom using the beam configuration of the actual treatment plan. In our QA procedures it was observed that the degree of agreement between the measurement and the calculation could vary from plan to plan, from linac to linac, as well as over time, with a discrepancy up to 8%. In this paper we examine one aspect of the process which can contribute to such poor reproducibility, namely, the leaf end position accuracy. A series of measurements was designed to irradiate an ion chamber using small beam segments where one multileaf collimator (MLC) edge covers half of the chamber. It was shown that the reproducibility varied up to 13%, which provides a possible explanation for the observed discrepancies above. A useful tool was also developed to measure ionization signals from individual segments of an IMRT sequence. In addition, an understanding of the leaf end position variations offers some insight into the overall quality of an IMRT dose distribution.

Entities:  

Mesh:

Year:  2005        PMID: 15986524     DOI: 10.1118/1.1901843

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Analysis of direct clinical consequences of MLC positional errors in volumetric-modulated arc therapy using 3D dosimetry system.

Authors:  Karthikeyan Nithiyanantham; Ganesh K Mani; Vikraman Subramani; Lutz Mueller; Karrthick K Palaniappan; Tejinder Kataria
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

2.  Quality assurance of MLC leaf position accuracy and relative dose effect at the MLC abutment region using an electronic portal imaging device.

Authors:  Iori Sumida; Hajime Yamaguchi; Hisao Kizaki; Masahiko Koizumi; Toshiyuki Ogata; Yutaka Takahashi; Yasuo Yoshioka
Journal:  J Radiat Res       Date:  2012-07-10       Impact factor: 2.724

3.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

4.  Dosimetric verification of micro-MLC based intensity modulated radiation therapy.

Authors:  Parminder Basran; Collins Yeboah
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

5.  On the sensitivity of patient-specific IMRT QA to MLC positioning errors.

Authors:  Guanghua Yan; Chihray Liu; Thomas A Simon; Lee-Cheng Peng; Christopher Fox; Jonathan G Li
Journal:  J Appl Clin Med Phys       Date:  2009-02-05       Impact factor: 2.102

6.  Detector system dose verification comparisons for arc therapy: couch vs. gantry mount.

Authors:  Arjunan Manikandan; Biplab Sarkar; Maitreyee Nandy; Chandra Sekaran Sureka; Michael S Gossman; Nadendla Sujatha; Vivek Thirupathur Rajendran
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

7.  Characterization of cylindrical ionization chambers for patient specific IMRT QA.

Authors:  Danielle Fraser; William Parker; Jan Seuntjens
Journal:  J Appl Clin Med Phys       Date:  2009-09-30       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.