Literature DB >> 15981109

Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy.

Justin S Smith1, Alfredo Quiñones-Hinojosa, Nicholas M Barbaro, Michael W McDermott.   

Abstract

OBJECT: As the availability of image-guided surgical navigation systems has increased, the application of frame-based biopsy has declined at our institution, despite equivalent accuracy and safety. There are several cost issues separating the use of surgical navigation systems and stereotactic frames for simple biopsy which may have implications in this era of health care cost control. We retrospectively reviewed the UCSF experience with stereotactic brain biopsy from a 9 year period.
METHODS: Data were collected for 213 consecutive stereotactic brain biopsies performed at UCSF (139 frame-based and 74 frameless). There were no significant differences between the frame-based and frameless biopsy groups with regard to patient demographics, overall histopathology, proportion of nondiagnostic biopsies, or incidence of complications. General anesthesia was used for 9 (6%) and 70 (95%) of the frame-based and frameless biopsy cases, respectively. Frame-based biopsies required a mean of 114+/-3 min of operating room time, while frameless biopsies required 185+/-6 min (P<0.0001). For patients admitted to our neurosurgery service who underwent frame-based (n=110) or frameless (n=52) biopsy within 24 h of admission, the mean lengths of hospital stay were 1.8+/-0.2 and 3.2+/-0.6 days, respectively (P=0.007).
CONCLUSION: Frame-based and frameless stereotactic biopsy approaches were equally effective at providing a tissue diagnosis with minimum morbidity and mortality. The frame-based approach, however, required significantly less anesthesia resources, less operating room time and shorter hospital stays, and thus should still be considered a first-line approach for stereotactic brain biopsy.

Entities:  

Mesh:

Year:  2005        PMID: 15981109     DOI: 10.1007/s11060-004-4208-3

Source DB:  PubMed          Journal:  J Neurooncol        ISSN: 0167-594X            Impact factor:   4.130


  20 in total

1.  Frameless stereotaxy with scalp-applied fiducial markers for brain biopsy procedures: experience in 218 cases.

Authors:  G H Barnett; D W Miller; J Weisenberger
Journal:  J Neurosurg       Date:  1999-10       Impact factor: 5.115

Review 2.  Frameless stereotaxy of the brain.

Authors:  J McInerney; D W Roberts
Journal:  Mt Sinai J Med       Date:  2000-09

3.  Failed stereotactic biopsy in a series of 518 cases.

Authors:  T M Soo; M Bernstein; J Provias; R Tasker; A Lozano; A Guha
Journal:  Stereotact Funct Neurosurg       Date:  1995       Impact factor: 1.875

4.  BrainLab VectorVision Neuronavigation System: technology and clinical experiences in 131 cases.

Authors:  H K Gumprecht; D C Widenka; C B Lumenta
Journal:  Neurosurgery       Date:  1999-01       Impact factor: 4.654

5.  Computed imaging stereotaxy: experience and perspective related to 500 procedures applied to brain masses.

Authors:  M L Apuzzo; P T Chandrasoma; D Cohen; C S Zee; V Zelman
Journal:  Neurosurgery       Date:  1987-06       Impact factor: 4.654

Review 6.  Role of stereotactic biopsy in the diagnosis and management of brain tumors.

Authors:  M D Krieger; P T Chandrasoma; C S Zee; M L Apuzzo
Journal:  Semin Surg Oncol       Date:  1998 Jan-Feb

7.  Magnetic resonance-guided stereotactic biopsies: results in 100 consecutive cases.

Authors:  D Fontaine; D Dormont; D Hasboun; S Clemenceau; C Valery; C Oppenheim; M Sahel; C Marsault; J Philippon; P Cornu
Journal:  Acta Neurochir (Wien)       Date:  2000       Impact factor: 2.216

8.  In vivo accuracy testing and clinical experience with the ISG Viewing Wand.

Authors:  E P Sipos; S A Tebo; S J Zinreich; D M Long; H Brem
Journal:  Neurosurgery       Date:  1996-07       Impact factor: 4.654

9.  Clinical experience with intracranial brain needle biopsy using frameless surgical navigation.

Authors:  I M Germano; J V Queenan
Journal:  Comput Aided Surg       Date:  1998

10.  Computed imaging-assisted stereotactic brain biopsy: a risk analysis of 225 consecutive cases.

Authors:  P D Sawin; P W Hitchon; K A Follett; J C Torner
Journal:  Surg Neurol       Date:  1998-06
View more
  24 in total

1.  Sensitivity analysis aimed at blood vessels detection using interstitial optical tomography during brain needle biopsy procedures.

Authors:  Julien Pichette; Andréanne Goyette; Fabien Picot; Marie-Andrée Tremblay; Gilles Soulez; Brian C Wilson; Frédéric Leblond
Journal:  Biomed Opt Express       Date:  2015-10-05       Impact factor: 3.732

2.  Assessment of image guided accuracy in a skull model: comparison of frameless stereotaxy techniques vs. frame-based localization.

Authors:  Alfredo Quiñones-Hinojosa; Marcus L Ware; Nader Sanai; Michael W McDermott
Journal:  J Neurooncol       Date:  2006-01       Impact factor: 4.130

Review 3.  Is the brain biopsy obligatory or not for the diagnosis of Schilder's disease? Review of the literature.

Authors:  Yuksel Yilmaz; Canan Kocaman; Hakan Karabagli; Memet Ozek
Journal:  Childs Nerv Syst       Date:  2007-08-25       Impact factor: 1.475

4.  Real-time MR-guided brain biopsy using 1.0-T open MRI scanner.

Authors:  Xiangmeng He; Ming Liu; Chao Liu; Jing Fang; Yujun Xu; Ligang Wang; Jianfeng Xiang; Roberto Blanco Sequeiros; Chengli Li
Journal:  Eur Radiol       Date:  2018-06-12       Impact factor: 5.315

5.  Assessment of molecular markers demonstrates concordance between samples acquired via stereotactic biopsy and open craniotomy in both anaplastic astrocytomas and glioblastomas.

Authors:  Florian Gessler; Peter Baumgarten; Joshua D Bernstock; Patrick Harter; Stephanie Lescher; Christian Senft; Volker Seifert; Gerhard Marquardt; Lutz Weise
Journal:  J Neurooncol       Date:  2017-05-15       Impact factor: 4.130

6.  Comparative effectiveness of frame-based, frameless, and intraoperative magnetic resonance imaging-guided brain biopsy techniques.

Authors:  Yi Lu; Cecil Yeung; Alireza Radmanesh; Robert Wiemann; Peter M Black; Alexandra J Golby
Journal:  World Neurosurg       Date:  2014-08-01       Impact factor: 2.104

7.  A modified stereotactic frame as an instrument holder for frameless stereotaxis: Technical note.

Authors:  Arun Angelo Patil
Journal:  Surg Neurol Int       Date:  2010-10-11

8.  Towards improving the safety and diagnostic yield of stereotactic biopsy in a single centre.

Authors:  Ruben Dammers; Joost W Schouten; Iain K Haitsma; Arnaud J P E Vincent; Johan M Kros; Clemens M F Dirven
Journal:  Acta Neurochir (Wien)       Date:  2010-08-01       Impact factor: 2.216

Review 9.  Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle.

Authors:  Christopher M Owen; Mark E Linskey
Journal:  J Neurooncol       Date:  2009-05-09       Impact factor: 4.130

10.  Fluorescein-assisted stereotactic needle biopsy of brain tumors: a single-center experience and systematic review.

Authors:  Giuseppe Catapano; Francesco Giovanni Sgulò; Vincenzo Seneca; Giuseppina Iorio; Matteo de Notaris; Giuseppe di Nuzzo
Journal:  Neurosurg Rev       Date:  2018-01-30       Impact factor: 3.042