Literature DB >> 15977729

Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: performance of a novel method during selected motor tasks.

Angelo Cappello1, Rita Stagni, Silvia Fantozzi, Alberto Leardini.   

Abstract

The purpose of the present work was to describe and assess the performance on two selected subjects of a new method for the compensation of soft tissue artifact on knee rotations and translations during the execution of step up/down, sit-to-stand/stand-to-sit, and flexion against gravity. Soft tissue artifact has been recognized as the most critical source of error in gait analysis data. Its propagation strongly affects joint angles, in particular those characterized by a small range of motion, such as knee ab/adduction and internal/external rotation. This may be critical in the exploitation of gait analysis data for clinical decisions. The proposed method is based on the flexion/extension angle interpolation of two anatomical landmark calibrations taken at the extremes of motion. Its performance on knee rotation and translations was tested on a kinematics data-set obtained by the synchronous combination of traditional stereophotogrammetry and 3-D fluoroscopy. The newly proposed method was extremely effective on the compensation of soft tissue artifact propagation to knee rotations, in particular mean values of the root mean square error on ab/adduction and internal/external rotation angles decreased from 3.7 degrees and 3.7 degrees to 1.4 degrees and 1.6 degrees, respectively, with respect to single calibration. Mainly, knee translations calculated from stereophotogrammetric data using the proposed compensation method were found to be reliable with respect to the fluoroscopy-based gold standard. The residual mean values of the root mean square error were 2.0, 2.8, and 2.1 mm for anterior/posterior, vertical, and medio/lateral translations, respectively.

Mesh:

Year:  2005        PMID: 15977729     DOI: 10.1109/TBME.2005.846728

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  10 in total

1.  Effects of different technical coordinate system definitions on the three dimensional representation of the glenohumeral joint centre.

Authors:  Amity Cree Campbell; J A Alderson; D G Lloyd; B C Elliott
Journal:  Med Biol Eng Comput       Date:  2009-03-13       Impact factor: 2.602

2.  Kinematic description of soft tissue artifacts: quantifying rigid versus deformation components and their relation with bone motion.

Authors:  Helios de Rosario; Alvaro Page; Antonio Besa; Vicente Mata; Efraim Conejero
Journal:  Med Biol Eng Comput       Date:  2012-10-26       Impact factor: 2.602

3.  IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

Authors:  Mahdi Zabat; Amina Ababou; Noureddine Ababou; Raphaël Dumas
Journal:  Med Biol Eng Comput       Date:  2019-08-30       Impact factor: 2.602

4.  An alternative technical marker set for the pelvis is more repeatable than the standard pelvic marker set.

Authors:  Maedeh Borhani; Alison H McGregor; Anthony M J Bull
Journal:  Gait Posture       Date:  2013-06-19       Impact factor: 2.840

5.  Are subject-specific musculoskeletal models robust to the uncertainties in parameter identification?

Authors:  Giordano Valente; Lorenzo Pitto; Debora Testi; Ajay Seth; Scott L Delp; Rita Stagni; Marco Viceconti; Fulvia Taddei
Journal:  PLoS One       Date:  2014-11-12       Impact factor: 3.240

6.  Description of soft tissue artifacts and related consequences on hindlimb kinematics during canine gait.

Authors:  Cheng-Chung Lin; Shi-Nuan Wang; Ming Lu; Tzu-Yi Chao; Tung-Wu Lu; Ching-Ho Wu
Journal:  PeerJ       Date:  2020-06-26       Impact factor: 2.984

7.  A Simple Algorithm for Assimilating Marker-Based Motion Capture Data During Periodic Human Movement Into Models of Multi-Rigid-Body Systems.

Authors:  Yasuyuki Suzuki; Takuya Inoue; Taishin Nomura
Journal:  Front Bioeng Biotechnol       Date:  2018-10-18

8.  Validity of inertial sensor based 3D joint kinematics of static and dynamic sport and physiotherapy specific movements.

Authors:  Wolfgang Teufl; Markus Miezal; Bertram Taetz; Michael Fröhlich; Gabriele Bleser
Journal:  PLoS One       Date:  2019-02-28       Impact factor: 3.240

9.  Application of Soft Tissue Artifact Compensation Using Displacement Dependency between Anatomical Landmarks and Skin Markers.

Authors:  Taebeum Ryu
Journal:  Anat Res Int       Date:  2012-07-19

10.  Reconstruction of skeletal movement using skin markers: comparative assessment of bone pose estimators.

Authors:  Andrea Cereatti; Ugo Della Croce; Aurelio Cappozzo
Journal:  J Neuroeng Rehabil       Date:  2006-03-23       Impact factor: 4.262

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.