Metal artifacts caused by gradient switching.

Hansjörg Graf1, Günter Steidle, Petros Martirosian, Ulrike A Lauer, Fritz Schick.   

Abstract

In metal parts, e.g., implants or instruments, eddy currents can be induced from gradient switching if positioned off-center inside the MR scanner. For the first time, a systematic analysis of related artifacts was performed. Current strength increases in conjunction with increasing size of the part, increasing electrical conductivity, distance from isocenter, and increasing gradient strengths. A xy-plane oriented copper ring (d(o) = 20 mm, d(i) = 15 mm, 2 mm thick) was examined at isocenter and at x = 15 cm, y = z = 0. Comparisons of xy-, xz-, and yz-slices, recorded for both possibilities to select encoding directions, revealed effects from ramp-down of the slice-selection and ramp-up of the read-out gradient. Near the metal part, temporary inhomogeneities were superimposed to the static field and spin-dephasing signal loss resulted, despite using spin-echo technique. Artifacts depended on excitation and read-out bandwidth. For an equivalent titanium ring, conductivity related effects could not be ascertained but distinct susceptibility effects occurred. MR compatibility of implants/instruments therefore requires both low susceptibility and low conductivity.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15968663     DOI: 10.1002/mrm.20524

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI.

Authors:  K Miyata; M Hasegawa; Y Abe; T Tabuchi; T Namiki; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  Influence of dental materials on dental MRI.

Authors:  O Tymofiyeva; S Vaegler; K Rottner; J Boldt; A J Hopfgartner; P C Proff; E J Richter; P M Jakob
Journal:  Dentomaxillofac Radiol       Date:  2013-04-22       Impact factor: 2.419

3.  Development and testing of implanted carbon electrodes for electromagnetic field mapping during neuromodulation.

Authors:  Neeta Ashok Kumar; Munish Chauhan; Sri Kirthi Kandala; Sung-Min Sohn; Rosalind J Sadleir
Journal:  Magn Reson Med       Date:  2020-04-16       Impact factor: 4.668

Review 4.  Advanced MRI strategies for assessing spinal cord injury.

Authors:  Seth A Smith; James J Pekar; Peter C M van Zijl
Journal:  Handb Clin Neurol       Date:  2012

5.  Characterizing the limits of MRI near metallic prostheses.

Authors:  Matthew R Smith; Nathan S Artz; Curtis Wiens; Diego Hernando; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-12-05       Impact factor: 4.668

6.  Novel Metal Artifact Reduction Techniques with Use of Slice-Encoding Metal Artifact Correction and View-Angle Tilting MR Imaging for Improved Visualization of Brain Tissue near Intracranial Aneurysm Clips.

Authors:  B Friedrich; M Wostrack; F Ringel; Y-M Ryang; A Förschler; S Waldt; C Zimmer; M Nittka; C Preibisch
Journal:  Clin Neuroradiol       Date:  2014-08-01       Impact factor: 3.649

7.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

8.  An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging.

Authors:  U Zanovello; L Matekovits; L Zilberti
Journal:  Sci Rep       Date:  2017-03-23       Impact factor: 4.379

9.  Comparisons of slice-encoding metal artifact correction and view-angle tilting magnetic resonance imaging and traditional digital radiography in evaluating chronic hip pain after total hip arthroplasty.

Authors:  Yimin Ma; Panli Zuo; Mathias Nittka; Xiaoguang Cheng; Hongyi Shao; Chen Wang
Journal:  J Orthop Translat       Date:  2017-12-20       Impact factor: 5.191

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.