Literature DB >> 12107316

Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis : a randomized, controlled trial.

Axel Pommer1, Gert Muhr, Andreas Dávid.   

Abstract

BACKGROUND: Complications of external fixation include loosening of the fixation pins and pin-track infection. Laboratory studies and clinical trials have suggested that hydroxyapatite coating improves the osteointegration of various orthopaedic implants. The purpose of this study was to determine whether the prevalence of pin-related complications can be reduced by the use of hydroxyapatite-coated pins in fixators applied for distraction osteogenesis.
METHODS: Forty-six consecutive patients undergoing segmental transport or lengthening of the tibia were randomized to the use of either standard titanium Schanz pins or hydroxyapatite-coated stainless-steel Schanz pins. The fixators were used for an average of thirty-eight weeks (range, fourteen to seventy-two weeks). All patients were closely monitored for pin loosening and infection, and digitized radiographs were assessed for bone resorption around all pins. When the external fixator was removed, the torque required to extract the pins was determined with use of an electronic torque wrench.
RESULTS: In the control group (titanium pins), twenty-two pins (13%) loosened and an infection occurred at the site of twenty pins. An extensive infection of the canal developed in one patient. Twenty-two pins were removed or replaced because of these complications. In the hydroxyapatite group, no clinical or radiographic signs of pin loosening or infection were observed and no pins required early removal or exchange. The mean torque (and standard deviation) required to remove the hydroxyapatite-coated pins was 0.43 0.18 N-m compared with 0.10 0.09 N-m for the uncoated pins (p < 0.001).
CONCLUSION: Coating pins with hydroxyapatite increases their fixation to bone and reduces the rate of infection and loosening during external fixation for distraction osteogenesis. Use of hydroxyapatite-coated pins should be considered in clinical situations requiring prolonged external fixation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12107316     DOI: 10.2106/00004623-200207000-00011

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  14 in total

1.  Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws.

Authors:  M Cimerman; A Cör; M Ceh; A Kristan; J Pizem; M Tonin
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

2.  The mechanics of external fixation.

Authors:  Austin T Fragomen; S Robert Rozbruch
Journal:  HSS J       Date:  2007-02

Review 3.  Ilizarov principles of deformity correction.

Authors:  B Spiegelberg; T Parratt; S K Dheerendra; W S Khan; R Jennings; D R Marsh
Journal:  Ann R Coll Surg Engl       Date:  2010-03       Impact factor: 1.891

Review 4.  External fixators in the treatment of midshaft clavicle non-unions: a systematic review.

Authors:  Tim Barlow; Piyush Upadhyay; David Barlow
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-20

Review 5.  "Ilizarov" external fixation: what the radiologist needs to know.

Authors:  Jonathan Tresley; Scott J Schoenleber; Adam D Singer; Paul Clifford
Journal:  Skeletal Radiol       Date:  2014-09-17       Impact factor: 2.199

Review 6.  External fixators: looking beyond the hardware maze.

Authors:  Kimia Khalatbari Kani; Jack A Porrino; Felix S Chew
Journal:  Skeletal Radiol       Date:  2019-09-12       Impact factor: 2.199

Review 7.  Ceramic and non-ceramic hydroxyapatite as a bone graft material: a brief review.

Authors:  S R Dutta; D Passi; P Singh; A Bhuibhar
Journal:  Ir J Med Sci       Date:  2014-11-27       Impact factor: 1.568

8.  Use of chlorhexidine-impregnated patch at pin site to reduce local morbidity: the ChIPPS Pilot Trial.

Authors:  Stephanie C Wu; Ryan T Crews; Charles Zelen; James S Wrobel; David G Armstrong
Journal:  Int Wound J       Date:  2008-06-01       Impact factor: 3.315

9.  Bisphosphonate-coated external fixation pins appear similar to hydroxyapatite-coated pins in the tibial metaphysis and to uncoated pins in the shaft.

Authors:  Sören Toksvig-Larsen; Per Aspenberg
Journal:  Acta Orthop       Date:  2013-04-28       Impact factor: 3.717

10.  In vivo measurement of bending stiffness in fracture healing.

Authors:  Reiner Hente; Jacques Cordey; Stephan M Perren
Journal:  Biomed Eng Online       Date:  2003-03-28       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.