Literature DB >> 15946861

Advantages of CCD detectors for de novo three-dimensional structure determination in single-particle electron microscopy.

B Sander1, M M Golas, H Stark.   

Abstract

For three-dimensional (3D) structure determination of large macromolecular complexes, single-particle electron cryomicroscopy is considered the method of choice. Within this field, structure determination de novo, as opposed to refinement of known structures, still presents a major challenge, especially for macromolecules without point-group symmetry. This is primarily because of technical issues: one of these is poor image contrast, and another is the often low particle concentration and sample heterogeneity imposed by the practical limits of biochemical purification. In this work, we tested a state-of-the art 4 k x 4 k charge-coupled device (CCD) detector (TVIPS TemCam-F415) to see whether or not it can contribute to improving the image features that are especially important for structure determination de novo. The present study is therefore focused on a comparison of film and CCD detector in the acquisition of images in the low-to-medium ( approximately 10-25 A) resolution range using a 200 kV electron microscope equipped with field emission gun. For comparison, biological specimens and radiation-insensitive carbon layers were imaged under various conditions to test the image phase transmission, spatial signal-to-noise ratio, visual image quality and power-spectral signal decay for the complete image-processing chain. At all settings of the camera, the phase transmission and spectral signal-to-noise ratio were significantly better on CCD than on film in the low-to-medium resolution range. Thus, the number of particle images needed for initial structure determination is reduced and the overall quality of the initial computed 3D models is improved. However, at high resolution, film is still significantly better than the CCD camera: without binning of the CCD camera and at a magnification of 70 kx, film is better beyond 21 A resolution. With 4-fold binning of the CCD camera and at very high magnification (> 300 kx) film is still superior beyond 7 A resolution.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15946861     DOI: 10.1016/j.jsb.2005.04.004

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  18 in total

1.  Direct visualization of secondary structures of F-actin by electron cryomicroscopy.

Authors:  Takashi Fujii; Atsuko H Iwane; Toshio Yanagida; Keiichi Namba
Journal:  Nature       Date:  2010-09-15       Impact factor: 49.962

2.  Ribosome dynamics and tRNA movement by time-resolved electron cryomicroscopy.

Authors:  Niels Fischer; Andrey L Konevega; Wolfgang Wintermeyer; Marina V Rodnina; Holger Stark
Journal:  Nature       Date:  2010-07-15       Impact factor: 49.962

3.  Merging molecular electron microscopy and mass spectrometry by carbon film-assisted endoproteinase digestion.

Authors:  Florian M Richter; Bjoern Sander; Monika M Golas; Holger Stark; Henning Urlaub
Journal:  Mol Cell Proteomics       Date:  2010-06-08       Impact factor: 5.911

4.  Direct electron detection yields cryo-EM reconstructions at resolutions beyond 3/4 Nyquist frequency.

Authors:  Benjamin E Bammes; Ryan H Rochat; Joanita Jakana; Dong-Hua Chen; Wah Chiu
Journal:  J Struct Biol       Date:  2012-01-21       Impact factor: 2.867

5.  Composition and three-dimensional EM structure of double affinity-purified, human prespliceosomal A complexes.

Authors:  Nastaran Behzadnia; Monika M Golas; Klaus Hartmuth; Bjoern Sander; Berthold Kastner; Jochen Deckert; Prakash Dube; Cindy L Will; Henning Urlaub; Holger Stark; Reinhard Lührmann
Journal:  EMBO J       Date:  2007-03-01       Impact factor: 11.598

6.  Self-assembly of a nanoscale DNA box with a controllable lid.

Authors:  Ebbe S Andersen; Mingdong Dong; Morten M Nielsen; Kasper Jahn; Ramesh Subramani; Wael Mamdouh; Monika M Golas; Bjoern Sander; Holger Stark; Cristiano L P Oliveira; Jan Skov Pedersen; Victoria Birkedal; Flemming Besenbacher; Kurt V Gothelf; Jørgen Kjems
Journal:  Nature       Date:  2009-05-07       Impact factor: 49.962

7.  Snapshots of the RNA editing machine in trypanosomes captured at different assembly stages in vivo.

Authors:  Monika M Golas; Cordula Böhm; Bjoern Sander; Kerstin Effenberger; Michael Brecht; Holger Stark; H Ulrich Göringer
Journal:  EMBO J       Date:  2009-02-05       Impact factor: 11.598

8.  A test-bed for optimizing high-resolution single particle reconstructions.

Authors:  Scott M Stagg; Gabriel C Lander; Joel Quispe; Neil R Voss; Anchi Cheng; Henry Bradlow; Steven Bradlow; Bridget Carragher; Clinton S Potter
Journal:  J Struct Biol       Date:  2008-05-06       Impact factor: 2.867

9.  Achievable resolution from images of biological specimens acquired from a 4k x 4k CCD camera in a 300-kV electron cryomicroscope.

Authors:  Dong-Hua Chen; Joanita Jakana; Xiangan Liu; Michael F Schmid; Wah Chiu
Journal:  J Struct Biol       Date:  2008-04-14       Impact factor: 2.867

10.  Detective quantum efficiency of electron area detectors in electron microscopy.

Authors:  G McMullan; S Chen; R Henderson; A R Faruqi
Journal:  Ultramicroscopy       Date:  2009-05-07       Impact factor: 2.689

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.