Literature DB >> 15925474

Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem A randomized study with use of radiostereometry and bone densitometry.

Peter Grant1, Arild Aamodt, Jan A Falch, Lars Nordsletten.   

Abstract

The custom made Unique stem is designed to fit closely to the metaphyseal region of the femur in order to obtain maximum mechanical stability and optimal load transfer. Thirty-seven patients (38 hips) with non-inflammatory arthritis were randomized to the uncemented custom made Unique stem or the Elite Plus stem inserted with cement. The patients have been followed clinically as well as with radiostereometry (RSA) and Dual-energy X-ray Absorptiometry (DXA) for 2 years. After 2 years the RSA result showed minimal translation and rotation for the Unique stem while the Elite Plus rotated slightly (mean 1.05 degrees) into retroversion. Compared to previous studies the Elite Plus was as stable as the Charnley prosthesis. The DXA results showed a significantly higher proximal and total (10% for the Unique versus 5% for Elite) bone loss for the Unique stem compared to the Elite Plus. Thus the optimal proximal press-fit of the custom made stem did secure a stable fixation, but did not decrease the proximal bone loss.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15925474     DOI: 10.1016/j.orthres.2005.03.016.1100230607

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  18 in total

1.  Fixation and bone remodeling around a low stiffness stem in revision surgery.

Authors:  Johan Kärrholm; Reza Razaznejad
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

2.  A prospective randomised radiostereometric analysis trial of SmartSet HV and Palacos R bone cements in primary total hip arthroplasty.

Authors:  Otto S Husby; Kristin Haugan; Pål Benum; Olav A Foss
Journal:  J Orthop Traumatol       Date:  2010-03-03

3.  Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Vanessa Wells; John R Field; Stuart A Callary
Journal:  Int Orthop       Date:  2009-12-13       Impact factor: 3.075

4.  Femoral remodeling around Charnley total hip arthroplasty is unpredictable.

Authors:  Matthew J Teusink; Katharine A Callaghan; Noelle F Klocke; Devon D Goetz; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

5.  Patient-specific devices and population-level evidence: evaluating therapeutic interventions with inherent variation.

Authors:  Mary Jean Walker
Journal:  Med Health Care Philos       Date:  2018-09

6.  Periprosthetic bone loss after insertion of an uncemented, customized femoral stem and an uncemented anatomical stem. A randomized DXA study with 5-year follow-up.

Authors:  Mona Nysted; Pål Benum; Jomar Klaksvik; Olav Foss; Arild Aamodt
Journal:  Acta Orthop       Date:  2011-06-14       Impact factor: 3.717

7.  Measurement of early bone loss around an uncemented femoral stem.

Authors:  Berte Bøe; Tore Heier; Lars Nordsletten
Journal:  Acta Orthop       Date:  2011-04-19       Impact factor: 3.717

8.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

9.  Female patients with low systemic BMD are prone to bone loss in Gruen zone 7 after cementless total hip arthroplasty.

Authors:  Jessica J Alm; Tatu J Mäkinen; Petteri Lankinen; Niko Moritz; Tero Vahlberg; Hannu T Aro
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

10.  Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Ali Abdulkarim; Prasad Ellanti; Nicola Motterlini; Tom Fahey; John M O'Byrne
Journal:  Orthop Rev (Pavia)       Date:  2013-03-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.