Strength and reliability of four-unit all-ceramic posterior bridges.

Heinz Lüthy1, Frank Filser, Olivier Loeffel, Madeleine Schumacher, Ludwig J Gauckler, Christoph H F Hammerle.   

Abstract

OBJECTIVES: The purpose of this study was to determine the in vitro load bearing capacity of four-unit posterior frameworks made of glass ceramic with lithium-disilicate crystals (E2), of zirconia-reinforced glass-infiltrated alumina (ICZ) and of zirconia stabilized with 3 mol% yttria (CEZ).
METHODS: All frameworks mimicked a four-unit posterior situation with 7.3 mm2 interdental cross-sections and possessed exactly the same dimensions. The load bearing capacity was measured on a special bridge test setup with 15 specimens for each of the materials. The data were analyzed with Weibull statistics giving the characteristic load bearing capacity F0 at 63% failure probability and the Weibull modulus m as indicator for the reliability and reproducibility.
RESULTS: For the E2 frameworks the average load bearing capacity and the SD was 260 (+/-53) N, the characteristic load F0 282 N and the reliability m = 5.7. For the ICZ frameworks the average load bearing capacity was 470 (+/-101) N, F0 518 N and m = 4.5. CEZ frameworks revealed the highest average load bearing capacity of 706 (+/-123) N, the highest characteristic load bearing capacity F0 = 755 N and the best reliability m = 7.0. SIGNIFICANCE: CEZ frameworks showed the best mechanical properties as demonstrated by the high values of average load bearing capacity, reliability and characteristic load bearing capacity with respect to the other ceramics studied. However, for four-unit posterior CEZ frameworks the connector size of 7.3 mm2 is insufficient to withstand occlusal forces reported in the literature. Four-unit posterior frameworks require a connector size larger than 7.3 mm2.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15923031     DOI: 10.1016/j.dental.2004.11.012

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  29 in total

1.  Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens.

Authors:  Bogna Stawarczyk; Andreas Ender; Albert Trottmann; Mutlu Özcan; Jens Fischer; Christoph H F Hämmerle
Journal:  Clin Oral Investig       Date:  2012-01-03       Impact factor: 3.573

2.  Adhesion of oral streptococci to all-ceramics dental restorative materials in vitro.

Authors:  R Meier; I Hauser-Gerspach; H Lüthy; J Meyer
Journal:  J Mater Sci Mater Med       Date:  2008-05-13       Impact factor: 3.896

3.  Impact of Gluma Desensitizer on the tensile strength of zirconia crowns bonded to dentin: an in vitro study.

Authors:  Bogna Stawarczyk; Leonie Hartmann; Rahel Hartmann; Malgorzata Roos; Andreas Ender; Mutlu Ozcan; Irena Sailer; Christoph H F Hämmerle
Journal:  Clin Oral Investig       Date:  2011-02-19       Impact factor: 3.573

4.  Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports.

Authors:  Katia Sarafidou; Meike Stiesch; Marc Philipp Dittmer; Daniela Jörn; Lothar Borchers; Philipp Kohorst
Journal:  Clin Oral Investig       Date:  2011-05-24       Impact factor: 3.573

5.  Strength of zirconia fixed partial dentures: review of the literature.

Authors:  M Gargari; F Gloria; A Cappello; L Ottria
Journal:  Oral Implantol (Rome)       Date:  2011-01-23

6.  Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test.

Authors:  G Sannino; A Pozzi; R Schiavetti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2012-07-17

7.  Fatigue of zirconia and dental bridge geometry: Design implications.

Authors:  G D Quinn; A R Studart; C Hebert; J R VerHoef; D Arola
Journal:  Dent Mater       Date:  2010-09-01       Impact factor: 5.304

Review 8.  A practical and systematic review of Weibull statistics for reporting strengths of dental materials.

Authors:  Janet B Quinn; George D Quinn
Journal:  Dent Mater       Date:  2009-11-28       Impact factor: 5.304

9.  Influence of finish line in the distribution of stress trough an all ceramic implant-supported crown.: A 3D Finite Element Analysis.

Authors:  G Sannino; F Gloria; L Ottria; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2010-03-04

10.  Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

Authors:  Josephine F Esquivel-Upshaw; Arthur E Clark; Jonathan J Shuster; Kenneth J Anusavice
Journal:  J Prosthodont       Date:  2013-06-12       Impact factor: 2.752

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.