Literature DB >> 15900674

Visualisation of the mandibular canal by different radiographic techniques.

C Lindh1, A Petersson, B Klinge.   

Abstract

6 mandibles were radiographically examined bilaterally to visualise the mandibular canal. 5 imaging techniques were used: periapical radiography, panoramic radiography, hypocycloidal tomography, spiral tomography and computed tomography (CT). Panoramic radiographs were obtained with 2 different X-ray machines. The CT-examinations comprised direct images and standard reconstructions based on axial slices. The specimens were subsequently sectioned for contact radiography. The visibility of the mandibular canal was estimated by 3 observers at special reference points on all radiographs and classified as clearly visible, questionable visibility or not visible. The contact radiographs served as the "gold standard". The inter-observer and the intra-observer agreement were assessed by calculating the overall agreement and the x value. Direct coronal computed tomography, as well as spiral and hypocycloidal tomography, gave better visualisation of the mandibular canal than periapical and panoramic radiography.

Mesh:

Year:  1992        PMID: 15900674     DOI: 10.1034/j.1600-0501.1992.030207.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  17 in total

1.  Appearance of the mandibular incisive canal on panoramic radiographs.

Authors:  R Jacobs; N Mraiwa; D Van Steenberghe; G Sanderink; M Quirynen
Journal:  Surg Radiol Anat       Date:  2004-06-10       Impact factor: 1.246

2.  Effect of electric potential and current on mandibular linear measurements in cone beam CT.

Authors:  S Panmekiate; W Apinhasmit; A Petersson
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

3.  Evaluation of bifid mandibular canals with cone-beam computed tomography in a Turkish adult population: a retrospective study.

Authors:  Kaan Orhan; Seçil Aksoy; Burak Bilecenoglu; Bayram Ufuk Sakul; Candan Semra Paksoy
Journal:  Surg Radiol Anat       Date:  2010-12-16       Impact factor: 1.246

4.  Descriptive study of mandibular canal visibility: morphometric and densitometric analysis for digital panoramic radiographs.

Authors:  Marius Kubilius; Ričardas Kubilius; Vaidas Varinauskas; Rimantas Žalinkevičius; Tolga F Tözüm; Gintaras Juodžbalys
Journal:  Dentomaxillofac Radiol       Date:  2016-05-31       Impact factor: 2.419

5.  Visibility of mandibular canal on panoramic radiograph after bilateral sagittal split osteotomy (BSSO).

Authors:  Constantinus Politis; Xiomara Botero Ramírez; Yi Sun; Ivo Lambrichts; Neil Heath; Jimoh Olubanwo Agbaje
Journal:  Surg Radiol Anat       Date:  2012-10-05       Impact factor: 1.246

6.  Bilateral bifid mandibular canal.

Authors:  Mahnaz Sheikhi; Hamid Badrian; Sajad Ghorbanizadeh
Journal:  Dent Res J (Isfahan)       Date:  2012-12

7.  The incidence and configuration of the bifid mandibular canal in Koreans by using cone-beam computed tomography.

Authors:  Ju-Han Kang; Kook-Sun Lee; Min-Gyu Oh; Hwa-Young Choi; Sae-Rom Lee; Song-Hee Oh; Yoon-Joo Choi; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang
Journal:  Imaging Sci Dent       Date:  2014-03-19

8.  Are different imaging methods affecting the treatment decision of extractions of mandibular third molars?

Authors:  Yifat Manor; Refael Abir; Alex Manor; Israel Kaffe
Journal:  Dentomaxillofac Radiol       Date:  2016-12-18       Impact factor: 2.419

9.  The effect of mandibular buccal tilting on the accuracy of posterior mandibular spiral tomographic images: An in vitro study.

Authors:  Mahnaz Sheikhi; Vida Maleki
Journal:  Dent Res J (Isfahan)       Date:  2011-12

10.  Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers.

Authors:  Kyung-Seok Hu; Da-Yae Choi; Won-Jae Lee; Hee-Jin Kim; Ui-Won Jung; Sungtae Kim
Journal:  J Periodontal Implant Sci       Date:  2012-04-30       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.