Literature DB >> 15895567

Cardiac cone-beam CT volume reconstruction using ART.

T Nielsen1, R Manzke, R Proksa, M Grass.   

Abstract

Modern computed tomography systems allow volume imaging of the heart. Up to now, approximately two-dimensional (2D) and 3D algorithms based on filtered backprojection are used for the reconstruction. These algorithms become more sensitive to artifacts when the cone angle of the x-ray beam increases as it is the current trend of computed tomography (CT) technology. In this paper, we investigate the potential of iterative reconstruction based on the algebraic reconstruction technique (ART) for helical cardiac cone-beam CT. Iterative reconstruction has the advantages that it takes the cone angle into account exactly and that it can be combined with retrospective cardiac gating fairly easily. We introduce a modified ART algorithm for cardiac CT reconstruction. We apply it to clinical cardiac data from a 16-slice CT scanner and compare the images to those obtained with a current analytical reconstruction method. In a second part, we investigate the potential of iterative reconstruction for a large area detector with 256 slices. For the clinical cases, iterative reconstruction produces excellent images of diagnostic quality. For the large area detector, iterative reconstruction produces images superior to analytical reconstruction in terms of cone-beam artifacts.

Mesh:

Year:  2005        PMID: 15895567     DOI: 10.1118/1.1869052

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  L0 constrained sparse reconstruction for multi-slice helical CT reconstruction.

Authors:  Yining Hu; Lizhe Xie; Limin Luo; Jean Claude Nunes; Christine Toumoulin
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

2.  Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Gerhard Kleinszig; Sebastian Vogt; Gary L Gallia; A Jay Khanna; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

3.  The impact of a new model-based iterative reconstruction algorithm on prosthetic heart valve related artifacts at reduced radiation dose MDCT.

Authors:  Dominika Suchá; Martin J Willemink; Pim A de Jong; Arnold M R Schilham; Tim Leiner; Petr Symersky; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-29       Impact factor: 2.357

4.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

5.  High-Biofidelity Biomodel Generated from Three-Dimensional Imaging (Cone-Beam Computed Tomography): A Methodological Proposal.

Authors:  Rosa Alicia Hernández-Vázquez; Guillermo Urriolagoitia-Sosa; Rodrigo Arturo Marquet-Rivera; Beatriz Romero-Ángeles; Octavio Alejandro Mastache-Miranda; Juan Alejandro Vázquez-Feijoo; Guillermo Urriolagoitia-Calderón
Journal:  Comput Math Methods Med       Date:  2020-01-28       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.