Literature DB >> 15875358

Peristat: a computer-based perimetry self-test for cost-effective population screening of glaucoma.

Tsontcho Ianchulev1, Peter Pham, Vladimir Makarov, Brian Francis, Don Minckler.   

Abstract

PURPOSE: Peristat is a virtual perimetry system that allows self-testing on any standard computer monitor via Internet connection. The sensitivity and specificity of Peristat to detect visual-field defects were compared to standard Humphrey Visual Field Analyzer data.
MATERIALS AND METHODS: In this prospective, comparative observational case series, 58 eyes of 33 patients were examined. Semiquantitative analyses compared Peristat and Humphrey Visual-Field scores. The study evaluated patients with an established glaucoma diagnosis, as well as glaucoma suspects who had undergone comprehensive ophthalmologic examinations including prior office perimetry evaluation (Humphrey Field Analyzer). Inclusion criteria were (1) diagnosis or suspicion of glaucoma, (2) BCVA better than 20/200, (3) reliable performance on prior standardized office perimetry, and (4) CDR greater than 0.5. Computer literacy was not required, and more than 40% of the patients tested were computer illiterate, with no previous computer or Internet experience. A total of 58 eyes of 33 patients were tested with the Humphrey and the Peristat systems: 10 eyes of 5 patients without documented glaucomatous field loss and 48 eyes of 23 patients with mild-to-severe scotomas by standard 24-2 office perimetry. A standard computer setup was used with a 17" monitor, and the Peristat system was enabled through a remote connection with a server.
RESULTS: All patients completed the Peristat test without difficulty. Testing time varied between 2 and 5 min, tending to be longer with more severe visual-field defects. Test results were reviewed, in a masked fashion, by two glaucoma specialists and one general ophthalmologist. The Peristat demonstrated a high degree of correlation with the Humphrey system. Among the three reviewers, sensitivity ranged from 80% to 83%. In a second subanalysis in which cases with mild defects were excluded, the Peristat's sensitivity increased to 84%-86% while specificity remained between 94% and 97% for all three reviewers. Patients performed the Peristat test with similar facility to their Humphrey test. Fixation losses and test reliability were comparable for both tests.
CONCLUSIONS: Peristat is a reliable self-test perimetry system that demonstrates high clinical utility for the detection of visual-field defects from glaucoma. Peristat could be a valuable public health tool for cost-effective screening of glaucoma.

Entities:  

Mesh:

Year:  2005        PMID: 15875358     DOI: 10.1080/02713680490522399

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  13 in total

1.  Patient autonomy and choice in healthcare: self-testing devices as a case in point.

Authors:  Anna-Marie Greaney; Dónal P O'Mathúna; P Anne Scott
Journal:  Med Health Care Philos       Date:  2012-11

2.  Pattern noise (PANO): a new automated functional glaucoma test.

Authors:  Sylvain El-Khoury; Thomas Hannen; Diana Carmen Dragnea; Faustin Ngounou; Paul-Rolf Preußner
Journal:  Int Ophthalmol       Date:  2017-08-16       Impact factor: 2.031

Review 3.  Spotlight on iPad Visual Field Tests Efficacy.

Authors:  Parul Ichhpujani; Hennaav Dhillon
Journal:  Clin Ophthalmol       Date:  2022-07-05

4.  The blue arc entoptic phenomenon in glaucoma (an American ophthalmological thesis).

Authors:  Louis R Pasquale; Steven Brusie
Journal:  Trans Am Ophthalmol Soc       Date:  2013-09

Review 5.  Teleglaucoma: improving access and efficiency for glaucoma care.

Authors:  Faazil Kassam; Kanagasingam Yogesan; Enitan Sogbesan; Louis R Pasquale; Karim F Damji
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Apr-Jun

6.  The effectiveness of teleglaucoma versus in-patient examination for glaucoma screening: a systematic review and meta-analysis.

Authors:  Sera-Melisa Thomas; Maya M Jeyaraman; Maya Jeyaraman; William G Hodge; Cindy Hutnik; John Costella; Monali S Malvankar-Mehta
Journal:  PLoS One       Date:  2014-12-05       Impact factor: 3.240

7.  Comparison of Peristat Online Perimetry with the Humphrey Perimetry in a Clinic-Based Setting.

Authors:  Eugene A Lowry; Jing Hou; Lauren Hennein; Robert T Chang; Shan Lin; Jeremy Keenan; Sean K Wang; Sean Ianchulev; Louis R Pasquale; Ying Han
Journal:  Transl Vis Sci Technol       Date:  2016-07-19       Impact factor: 3.283

8.  Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.

Authors:  Stylianos Tsapakis; Dimitrios Papaconstantinou; Andreas Diagourtas; Konstantinos Droutsas; Konstantinos Andreanos; Marilita M Moschos; Dimitrios Brouzas
Journal:  Clin Ophthalmol       Date:  2017-08-07

9.  Home-based visual field test for glaucoma screening comparison with Humphrey perimeter.

Authors:  Stylianos Tsapakis; Dimitrios Papaconstantinou; Andreas Diagourtas; Stylianos Kandarakis; Konstantinos Droutsas; Konstantinos Andreanos; Dimitrios Brouzas
Journal:  Clin Ophthalmol       Date:  2018-12-12

10.  Visual field examination using a video projector: comparison with Humphrey perimeter.

Authors:  Dimitrios Brouzas; Stylianos Tsapakis; Eirini Nitoda; Marilita M Moschos
Journal:  Clin Ophthalmol       Date:  2014-03-11