Optimal electrolytic chloriding of silver ink electrodes for use in electrical impedance tomography.

E T McAdams1, P Henry, J M Anderson, J Jossinet.   

Abstract

The electrode-electrolyte interface impedance may be simplistically modelled by an equivalent circuit comprising a resistance, RTOTAL, in series with an empirical, constant phase angle impedance, ZCPA. This pseudo-capacitance can be thought of as representing empirically the non-faradaic, double layer capacitance in the presence of specific adsorption and surface roughness effects. RTOTAL is the sum of the lead and electrolyte resistances. Depositing a thin layer of silver chloride on silver electrodes can yield improved electrical performance characteristics (potential and impedance) when used in conjunction with a chloride gel. An electrolytically deposited AgCl layer tends to have a rough surface profile thus leading to an increase in the effective interface area. This gives rise to a decrease in RTOTAL and ZCPA, both of which are desirable. Unfortunately AgCl is a relatively poor conductor. Increasing layer thickness causes RTOTAL to increase, thus adversely affecting the inter-electrode impedance at high frequencies. Electrode systems for use in electrical impedance tomography therefore require only relatively thin layers of AgCl.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1587099     DOI: 10.1088/0143-0815/13/a/004

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  5 in total

1.  Accuracy of an optically isolated tetra-polar impedance measurement system.

Authors:  S Nebuya; M Noshiro; B H Brown; R H Smallwood; P Milnes
Journal:  Med Biol Eng Comput       Date:  2002-11       Impact factor: 2.602

Review 2.  Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography.

Authors:  E T McAdams; J Jossinet; A Lackermeier; F Risacher
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

3.  Different displacement of bioimpedance vector due to Ag/AgCl electrode effect.

Authors:  L Nescolarde; H Lukaski; A De Lorenzo; B de-Mateo-Silleras; M P Redondo-Del-Río; M A Camina-Martín
Journal:  Eur J Clin Nutr       Date:  2016-07-06       Impact factor: 4.016

4.  Sensor spacing affects the tissue impedance spectra of rabbit ventricular epicardium.

Authors:  Charlotte Mae K Waits; Roger C Barr; Andrew E Pollard
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-04-28       Impact factor: 4.733

5.  Evaluating Major Electrode Types for Idle Biological Signal Measurements for Modern Medical Technology.

Authors:  Anas Albulbul
Journal:  Bioengineering (Basel)       Date:  2016-08-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.