Accuracy of an optically isolated tetra-polar impedance measurement system.

S Nebuya1, M Noshiro, B H Brown, R H Smallwood, P Milnes.   

Abstract

Accurate electrical transfer impedance measurement at the high frequencies (> 1 MHz) required to characterise blood and intracellular structures is very difficult, owing to stray capacitances between lead wires. To solve this problem, an optically isolated measurement system has been developed using a phase-locked-loop technique for synchronisation between current injection (drive) and voltage measurement (receive) circuits. The synchronisation error between drive and receive circuits was less than 1 ns. The accuracy and reproducibility of the developed system was examined using a tissue equivalent Cole model consisting of two resistors and one capacitor. The absolute value Z and phase shift theta in impedance of the Cole model was measured at 1.25 MHz by both an LCR meter and the isolated measurement system. The difference between the values measured by the isolated measurement system and those measured by the LCR meter was less than 0.27omega (2.9%) in Z and 0.79 degree in theta. The standard deviation was less than 0.09 omega in Z and 0.60 degree in theta.

Entities:  

Mesh:

Year:  2002        PMID: 12507315     DOI: 10.1007/bf02345303

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  4 in total

1.  Parametric modelling for electrical impedance spectroscopy system.

Authors:  L Lu; L Hamzaoui; B H Brown; B Rigaud; R H Smallwood; D C Barber; J P Morucci
Journal:  Med Biol Eng Comput       Date:  1996-03       Impact factor: 2.602

2.  A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy.

Authors:  H Scharfetter; P Hartinger; H Hinghofer-Szalkay; H Hutten
Journal:  Physiol Meas       Date:  1998-05       Impact factor: 2.833

3.  Optimal electrolytic chloriding of silver ink electrodes for use in electrical impedance tomography.

Authors:  E T McAdams; P Henry; J M Anderson; J Jossinet
Journal:  Clin Phys Physiol Meas       Date:  1992

4.  Relation between tissue structure and imposed electrical current flow in cervical neoplasia.

Authors:  B H Brown; J A Tidy; K Boston; A D Blackett; R H Smallwood; F Sharp
Journal:  Lancet       Date:  2000-03-11       Impact factor: 79.321

  4 in total
  1 in total

1.  Frequency-domain reconstruction of signals in electrical bioimpedance spectroscopy.

Authors:  Aleksander S Paterno; Rodrigo A Stiz; Pedro Bertemes-Filho
Journal:  Med Biol Eng Comput       Date:  2009-10       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.