A practical gait analysis system using gyroscopes.

K Tong1, M H Granat.   

Abstract

This study investigated the possibility of using uni-axial gyroscopes to develop a simple portable gait analysis system. Gyroscopes were attached on the skin surface of the shank and thigh segments and the angular velocity for each segment was recorded in each segment. Segment inclinations and knee angle were derived from segment angular velocities. The angular signals from a motion analysis system were used to evaluate the angular velocities and the derived signals from the gyroscopes. There was a good correlation between these signals. When performing a turn the signals of segment inclination and knee angle drifted. Two methods were used to solve this: automatically resetting the system to re-initialise the angle in each gait cycle, and high-pass filtering. They both successfully corrected this drift. A single gyroscope on the shank segment could provide information on segment inclination range, cadence, number of steps, and an estimation of stride length and walking speed.

Entities:  

Mesh:

Year:  1999        PMID: 10426508     DOI: 10.1016/s1350-4533(99)00030-2

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  66 in total

1.  An adaptive gyroscope-based algorithm for temporal gait analysis.

Authors:  Barry R Greene; Denise McGrath; Ross O'Neill; Karol J O'Donovan; Adrian Burns; Brian Caulfield
Journal:  Med Biol Eng Comput       Date:  2010-11-02       Impact factor: 2.602

2.  Reliability of the step phase detection using inertial measurement units: pilot study.

Authors:  Salvatore Sessa; Massimiliano Zecca; Luca Bartolomeo; Takamichi Takashima; Hiroshi Fujimoto; Atsuo Takanishi
Journal:  Healthc Technol Lett       Date:  2015-03-31

3.  BioKin: an ambulatory platform for gait kinematic and feature assessment.

Authors:  Samitha W Ekanayake; Andrew J Morris; Mike Forrester; Pubudu N Pathirana
Journal:  Healthc Technol Lett       Date:  2015-02-25

4.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers.

Authors:  H J Luinge; P H Veltink
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

5.  Support vector machine for classification of walking conditions using miniature kinematic sensors.

Authors:  Hong-Yin Lau; Kai-Yu Tong; Hailong Zhu
Journal:  Med Biol Eng Comput       Date:  2008-03-18       Impact factor: 2.602

6.  Two simple methods for determining gait events during treadmill and overground walking using kinematic data.

Authors:  J A Zeni; J G Richards; J S Higginson
Journal:  Gait Posture       Date:  2007-08-27       Impact factor: 2.840

7.  Understanding the effects of pre-processing on extracted signal features from gait accelerometry signals.

Authors:  Alexandre Millecamps; Kristin A Lowry; Jennifer S Brach; Subashan Perera; Mark S Redfern; Ervin Sejdić
Journal:  Comput Biol Med       Date:  2015-04-04       Impact factor: 4.589

8.  Command control for functional electrical stimulation hand grasp systems using miniature accelerometers and gyroscopes.

Authors:  K Y Tong; A F T Mak; W Y Ip
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

9.  Control of triceps surae stimulation based on shank orientation using a uniaxial gyroscope during gait.

Authors:  C C Monaghan; W J B M van Riel; P H Veltink
Journal:  Med Biol Eng Comput       Date:  2009-10-15       Impact factor: 2.602

10.  Motion analysis of sun salutation using magnetometer and accelerometer.

Authors:  Sn Omkar; Meenakshi Mour; Debarun Das
Journal:  Int J Yoga       Date:  2009-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.