Literature DB >> 15864671

Compliance of the L5-S1 spinal unit: a comparative study between an unconstrained and a partially constrained system.

E A Charriere1, T Beutler, M Caride, P Mordasini, T E Orr, P K Zysset.   

Abstract

A comparison between an unconstrained and a partially constrained system for in vitro biomechanical testing of the L5-S1 spinal unit was conducted. The objective was to compare the compliance and the coupling of the L5-S1 unit measured with an unconstrained and a partially constrained test for the three major physiological motions of the human spine. Very few studies have compared unconstrained and partially constrained testing systems using the same cadaveric functional spinal units (FSUs). Seven human L5-S1 units were therefore tested on both a pneumatic, unconstrained, and a servohydraulic, partially constrained system. Each FSU was tested along three motions: flexion-extension (FE), lateral bending (LB) and axial rotation (AR). The obtained kinematics on both systems is not equivalent, except for the FE case, where both motions are similar. The directions of coupled motions were similar for both tests, but their magnitudes were smaller in the partially constrained configuration. The use of a partially constrained system to characterize LB and AR of the lumbosacral FSU decreased significantly the measured stiffness of the segment. The unconstrained system is today's "gold standard" for the characterization of FSUs. The selected partially constrained method seems also to be an appropriate way to characterize FSUs for specific applications. Care should be taken using the latter method when the coupled motions are important.

Entities:  

Mesh:

Year:  2005        PMID: 15864671      PMCID: PMC3454568          DOI: 10.1007/s00586-004-0807-0

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  31 in total

1.  Intersegmental spinal flexibility with lumbosacral instrumentation. An in vitro biomechanical investigation.

Authors:  T Asazuma; I A Stokes; M S Moreland; N Suzuki
Journal:  Spine (Phila Pa 1976)       Date:  1990-11       Impact factor: 3.468

2.  Axial rotation of the lumbar spine and the effect of flexion. An in vitro and in vivo biomechanical study.

Authors:  R Gunzburg; W Hutton; R Fraser
Journal:  Spine (Phila Pa 1976)       Date:  1991-01       Impact factor: 3.468

Review 3.  Biomechanics of posterior lumbar fixation. Analysis of testing methodologies.

Authors:  W T Edwards
Journal:  Spine (Phila Pa 1976)       Date:  1991-10       Impact factor: 3.468

4.  Biomechanical evaluation of spinal fixation devices. Part III. Stability provided by six spinal fixation devices and interbody bone graft.

Authors:  K Abumi; M M Panjabi; J Duranceau
Journal:  Spine (Phila Pa 1976)       Date:  1989-11       Impact factor: 3.468

5.  Mechanical testing of spinal instrumentation.

Authors:  R B Ashman; J G Birch; L B Bone; J D Corin; J A Herring; C E Johnston; J F Ritterbush; J W Roach
Journal:  Clin Orthop Relat Res       Date:  1988-02       Impact factor: 4.176

6.  Effect of testing mode on the biomechanical response of a spinal motion segment.

Authors:  Y E Kim; V K Goel
Journal:  J Biomech       Date:  1990       Impact factor: 2.712

7.  The effect of facet geometry on the axial torque-rotation response of lumbar motion segments.

Authors:  A M Ahmed; N A Duncan; D L Burke
Journal:  Spine (Phila Pa 1976)       Date:  1990-05       Impact factor: 3.468

8.  A study of stiffness protocol as exemplified by testing of a burst fracture model in sagittal plane.

Authors:  M M Panjabi; Y Kato; H Hoffman; J Cholewicki; M Krag
Journal:  Spine (Phila Pa 1976)       Date:  2000-11-01       Impact factor: 3.468

9.  The effect of injury on rotational coupling at the lumbosacral joint. A biomechanical investigation.

Authors:  T R Oxland; J J Crisco; M M Panjabi; I Yamamoto
Journal:  Spine (Phila Pa 1976)       Date:  1992-01       Impact factor: 3.468

10.  Constrained testing conditions affect the axial rotation response of lumbar functional spinal units.

Authors:  S Grassmann; T R Oxland; U Gerich; L P Nolte
Journal:  Spine (Phila Pa 1976)       Date:  1998-05-15       Impact factor: 3.468

View more
  2 in total

Review 1.  Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis.

Authors:  Chaofei Zhang; Erin M Mannen; Hadley L Sis; Eileen S Cadel; Benjamin M Wong; Wenjun Wang; Bo Cheng; Elizabeth A Friis; Dennis E Anderson
Journal:  J Biomech       Date:  2019-12-16       Impact factor: 2.712

Review 2.  In Silico Meta-Analysis of Boundary Conditions for Experimental Tests on the Lumbar Spine.

Authors:  Simone Borrelli; Giovanni Putame; Giulia Pascoletti; Mara Terzini; Elisabetta M Zanetti
Journal:  Ann Biomed Eng       Date:  2022-07-29       Impact factor: 4.219

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.