PURPOSE: To investigate prospectively the relative accuracy of computed tomographic (CT) angiography, calcium scoring (CS), and both methods combined in demonstrating coronary artery stenoses by using conventional angiography as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board Human Research Ethics Committee, and all patients completed written informed consent. Fifty patients (40 men, 10 women) aged 62 years +/- 11 (+/- standard deviation) who were suspected of having coronary artery disease underwent both conventional coronary angiography and multisection coronary CT angiography with CS. Sensitivity and specificity of CS, CT angiography, and both methods combined in demonstrating luminal stenosis greater than or equal to 50% were determined for each arterial segment, coronary vessel, and patient. Receiver operating characteristic (ROC) curves were generated for CS prediction of significant stenosis, and the Mann-Whitney U test was used for comparison of CS between groups. RESULTS: When used with segment-specific electrocardiographic phase reconstructions, CT angiography demonstrated stenosed segments with 79% sensitivity and 95% specificity. Mean calcium score was greater in segments, vessels, and patients with stenoses than in segments, vessels, and patients without stenoses (P < .001 for all); nine (16%) of 56 stenosed segments, however, had a calcium score of 0. The patient calcium score correlated strongly with the number of stenosed arteries (Spearman rho = 0.75, P < .001). CS was more accurate in demonstrating stenosis in patients than in segments (areas under ROC curve were 0.88 and 0.74, respectively). CT angiography, however, was more accurate than CS in demonstrating stenosis in patients, vessels, and segments. The sensitivity and specificity of CS varied according to the threshold used, but when the calcium score cutoff (ie, >150) matched the specificity of CT angiography (95%), the sensitivity of CS in demonstrating stenosed segments was 29% (compared with 79% for CT angiography). Combining CT angiography with CS (at threshold of 400) improved the sensitivity of CT angiography (from 93% to 100%) in demonstrating significant coronary disease in patients, without a loss of specificity (85%); this finding, however, was not statistically significant. CONCLUSION: CT angiography is more accurate than CS in demonstrating coronary stenoses. A patient calcium score of greater than or equal to 400, however, can be used to potentially identify patients with significant coronary stenoses not detected at CT angiography. (c) RSNA, 2005.
PURPOSE: To investigate prospectively the relative accuracy of computed tomographic (CT) angiography, calcium scoring (CS), and both methods combined in demonstrating coronary artery stenoses by using conventional angiography as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board Human Research Ethics Committee, and all patients completed written informed consent. Fifty patients (40 men, 10 women) aged 62 years +/- 11 (+/- standard deviation) who were suspected of having coronary artery disease underwent both conventional coronary angiography and multisection coronary CT angiography with CS. Sensitivity and specificity of CS, CT angiography, and both methods combined in demonstrating luminal stenosis greater than or equal to 50% were determined for each arterial segment, coronary vessel, and patient. Receiver operating characteristic (ROC) curves were generated for CS prediction of significant stenosis, and the Mann-Whitney U test was used for comparison of CS between groups. RESULTS: When used with segment-specific electrocardiographic phase reconstructions, CT angiography demonstrated stenosed segments with 79% sensitivity and 95% specificity. Mean calcium score was greater in segments, vessels, and patients with stenoses than in segments, vessels, and patients without stenoses (P < .001 for all); nine (16%) of 56 stenosed segments, however, had a calcium score of 0. The patient calcium score correlated strongly with the number of stenosed arteries (Spearman rho = 0.75, P < .001). CS was more accurate in demonstrating stenosis in patients than in segments (areas under ROC curve were 0.88 and 0.74, respectively). CT angiography, however, was more accurate than CS in demonstrating stenosis in patients, vessels, and segments. The sensitivity and specificity of CS varied according to the threshold used, but when the calcium score cutoff (ie, >150) matched the specificity of CT angiography (95%), the sensitivity of CS in demonstrating stenosed segments was 29% (compared with 79% for CT angiography). Combining CT angiography with CS (at threshold of 400) improved the sensitivity of CT angiography (from 93% to 100%) in demonstrating significant coronary disease in patients, without a loss of specificity (85%); this finding, however, was not statistically significant. CONCLUSION: CT angiography is more accurate than CS in demonstrating coronary stenoses. A patient calcium score of greater than or equal to 400, however, can be used to potentially identify patients with significant coronary stenoses not detected at CT angiography. (c) RSNA, 2005.
Authors: Gaetano Nucifora; Joanne D Schuijf; Jacob M van Werkhoven; J Wouter Jukema; Roxana Djaberi; Arthur J H A Scholte; Albert de Roos; Martin J Schalij; Ernst E van der Wall; Jeroen J Bax Journal: J Nucl Cardiol Date: 2009-02-14 Impact factor: 5.952
Authors: Christian Thilo; Mulugeta Gebregziabher; Florian B Mayer; Peter L Zwerner; Philip Costello; U Joseph Schoepf Journal: Eur Radiol Date: 2009-10-28 Impact factor: 5.315
Authors: Paul Stolzmann; Hatem Alkadhi; Hans Scheffel; André Plass; Sebastian Leschka; Volkmar Falk; Sebastian Kozerke; Christophe Wyss; Olivio F Donati Journal: Int J Cardiovasc Imaging Date: 2010-10-31 Impact factor: 2.357
Authors: Francesca Pugliese; M G M Hunink; Willem B Meijboom; Katarzyna Gruszczynsnka; Marco Rengo; Lu Zou; Ian Baron; Marcel L Dijkshoorn; Gabriel P Krestin; Pim J de Feyter Journal: Int J Cardiovasc Imaging Date: 2015-09-14 Impact factor: 2.357