Literature DB >> 15855361

Long-term results of the cementless porous-coated anatomic total hip prosthesis.

Y-H Kim1.   

Abstract

Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration of the clinical and radiological follow-up was 19.4 years (18 to 20). The mean Harris hip score initially improved from 55 points before to 95 points at two years after operation, but subsequently decreased to 91 points after six years, 87 points after 11.2 years, and 85 points after 19.4 years. At the final follow-up, 23 hips (18%) of the entire cohort and 21% of survivors had undergone revision because of loosening or osteolysis of the acetabular component and eight hips (6%) of the entire cohort and 7% of survivors for loosening or osteolysis of the femoral component. Only four femoral components (4%) were revised for isolated aseptic loosening without osteolysis and two (2%) for recurrent dislocation. On the basis of these long-term results, the porous-coated anatomic femoral component survived for a minimum of 18 years after operation while the acetabular component was less durable. The findings identify the principles of uncemented joint replacement which can be applied to current practice.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15855361     DOI: 10.1302/0301-620X.87B5.15554

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  19 in total

1.  Enhanced cell integration to titanium alloy by surface treatment with microarc oxidation: a pilot study.

Authors:  Young Wook Lim; Soon Yong Kwon; Doo Hoon Sun; Hyoun Ee Kim; Yong Sik Kim
Journal:  Clin Orthop Relat Res       Date:  2009-05-12       Impact factor: 4.176

2.  Survival of the cementless Spotorno stem in the second decade.

Authors:  Peter R Aldinger; Alexander W Jung; Steffen J Breusch; Volker Ewerbeck; Dominik Parsch
Journal:  Clin Orthop Relat Res       Date:  2009-06-06       Impact factor: 4.176

3.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

4.  Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips.

Authors:  Bertrand Boyer; Rémi Philippot; Jean Geringer; Frédéric Farizon
Journal:  Int Orthop       Date:  2011-06-23       Impact factor: 3.075

5.  Dual offset metaphyseal-filling stems in primary total hip arthroplasty in dysplastic hips after a minimum follow-up of ten years.

Authors:  Goksel Dikmen; Vahit Emre Ozden; Burak Beksac; Ismail Remzi Tozun
Journal:  Int Orthop       Date:  2018-09-19       Impact factor: 3.075

6.  Intraprosthetic dislocation: a specific complication of the dual-mobility system.

Authors:  Remi Philippot; Bertrand Boyer; Frederic Farizon
Journal:  Clin Orthop Relat Res       Date:  2012-10-10       Impact factor: 4.176

7.  A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

Authors:  Ryan G Molli; Adolph V Lombardi; Keith R Berend; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

8.  A monoblock porous tantalum acetabular cup has no osteolysis on CT at 10 years.

Authors:  Todd C Moen; Raju Ghate; Noel Salaz; Jason Ghodasra; S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

9.  Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older.

Authors:  Keijo T Mäkelä; Antti Eskelinen; Pekka Paavolainen; Pekka Pulkkinen; Ville Remes
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

10.  Long-term (20- to 25-year) results of an uncemented tapered titanium femoral component and factors affecting survivorship.

Authors:  Marcus R Streit; Moritz M Innmann; Christian Merle; Thomas Bruckner; Peter R Aldinger; Tobias Gotterbarm
Journal:  Clin Orthop Relat Res       Date:  2013-05-14       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.