Literature DB >> 15851559

Dynamic changes in the tear film in dry eyes.

Robert Montés-Micó1, Jorge L Alió, W Neil Charman.   

Abstract

PURPOSE: To examine the dynamics of the tear film in patients with dry eye by measuring the wavefront aberrations of the anterior surface of the film.
METHODS: Anterior surface aberrations for a 7-mm pupil were determined in 13 patients with dry eye at 1-second time intervals, for 15 seconds after a blink. The aberrations were calculated from the elevations provided by corneal topography. All data were decomposed using Zernike polynomials. Total, spherical, and comalike aberrations terms were studied separately. Results were compared with those in normal eyes. Outcome measures included comparison with clinical tear breakup time measurements.
RESULTS: The total root mean square (RMS) wavefront aberration in patients with dry eye passed through in a minimum of 2.9 +/- 0.4 seconds after a blink in comparison to the minimum at 6.1 +/- 0.5 seconds in normal patients. In both groups, the minimum in total aberration appeared to be associated with similar changes in comalike aberrations, rather than in spherical aberrations, which increased monotonically with time. The time at which minimum RMS aberration occurred correlated reasonably well with the measured tear breakup times.
CONCLUSIONS: Measurements of the dynamic changes in the optical aberrations introduced by the anterior tear film surface give valuable insights into tear film changes and may provide a convenient objective method for the diagnosis of dry eye.

Entities:  

Mesh:

Year:  2005        PMID: 15851559     DOI: 10.1167/iovs.05-0017

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  30 in total

1.  Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics.

Authors:  Yoko Hirohara; Toshifumi Mihashi; Shizuka Koh; Sayuri Ninomiya; Naoyuki Maeda; Takashi Fujikado
Journal:  Jpn J Ophthalmol       Date:  2007-08-03       Impact factor: 2.447

2.  Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors.

Authors:  Ayeswarya Ravikumar; Jason D Marsack; Harold E Bedell; Yue Shi; Raymond A Applegate
Journal:  J Vis       Date:  2013-11-26       Impact factor: 2.240

3.  Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.

Authors:  Stephen C Pflugfelder
Journal:  Am J Ophthalmol       Date:  2011-10-22       Impact factor: 5.258

4.  Measurement of the time course of optical quality and visual deterioration during tear break-up.

Authors:  Haixia Liu; Larry Thibos; Carolyn G Begley; Arthur Bradley
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-01-27       Impact factor: 4.799

5.  Dynamic changes in the air-tear film interface modulation transfer function.

Authors:  Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó; Alejandro Cerviño; Jose M González-Méijome
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-09-25       Impact factor: 3.117

Review 6.  Dynamics and function of the tear film in relation to the blink cycle.

Authors:  R J Braun; P E King-Smith; C G Begley; Longfei Li; N R Gewecke
Journal:  Prog Retin Eye Res       Date:  2014-12-03       Impact factor: 21.198

7.  Ocular surface evaluation in eyes with chronic glaucoma on long term topical antiglaucoma therapy.

Authors:  Manu Saini; Murugesan Vanathi; Tanuj Dada; Tushar Agarwal; Rebika Dhiman; Sudarshan Khokhar
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

8.  Time course of changes in ocular wavefront aberration after administration of eye ointment.

Authors:  T Hiraoka; T Yamamoto; F Okamoto; T Oshika
Journal:  Eye (Lond)       Date:  2012-07-20       Impact factor: 3.775

9.  Characteristics of symptoms experienced by persons with dry eye disease while driving in China.

Authors:  Y Wang; H Lv; Y Liu; X Jiang; M Zhang; X Li; W Wang
Journal:  Eye (Lond)       Date:  2017-06-16       Impact factor: 3.775

10.  Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system.

Authors:  Jing Dong; Qiang Wu; Xiao-Gang Wang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

View more