Literature DB >> 1584916

Contrast-enhanced MR imaging of the lung: assessments of ventilation and perfusion.

Y Berthezène1, V Vexler, O Clément, A Mühler, M E Moseley, R C Brasch.   

Abstract

The use of aerosolized gadopentetate dimeglumine to define regional lung ventilation and of intravenously administered polylysine-(gadopentetate dimeglumine)40 to assess regional lung perfusion was investigated. In 10 healthy rats who breathed aerosolized gadopentetate dimeglumine (0.25 mol/L) for 5 minutes, pulmonary signal intensity increased diffusely in both lungs by more than 70%. When the same animals received intravenously administered polylysine-(gadopentetate dimeglumine)40 (0.1 mmol of gadolinium per kilogram), there was an additional 300% enhancement of the pulmonary parenchyma. In a rat model of acute unilateral pulmonary embolism (n = 5), perfusion defects were identified after administration of polylysine-(gadopentetate dimeglumine)40, but no ventilation abnormality was seen after inhalation of gadopentetate dimeglumine. In a rat model of acute unilateral airway obstruction (n = 5), only the ventilated right lung enhanced after inhalation of gadopentetate dimeglumine. In four of these animals, the focal ventilation defect was accompanied by a matched decrease in perfusion, seen after enhancement of the blood pool with polylysine-(gadopentetate dimeglumine)40.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1584916     DOI: 10.1148/radiology.183.3.1584916

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Vascular and perfusion imaging using encapsulated laser-polarized helium.

Authors:  V Callot; E Canet; J Brochot; Y Berthezène; M Viallon; H Humblot; A Briguet; H Tournier; Y Crémillieux
Journal:  MAGMA       Date:  2001-03       Impact factor: 2.310

2.  Detection of small pulmonary nodules in high-field MR at 3 T: evaluation of different pulse sequences using porcine lung explants.

Authors:  M Regier; S Kandel; M G Kaul; B Hoffmann; H Ittrich; P M Bansmann; J Kemper; C Nolte-Ernsting; M Heller; G Adam; J Biederer
Journal:  Eur Radiol       Date:  2006-09-30       Impact factor: 5.315

3.  Quantitative biodistribution and pharmacokinetics of multimodal gadolinium-based nanoparticles for lungs using ultrashort TE MRI.

Authors:  Andrea Bianchi; Sandrine Dufort; François Lux; Arnaud Courtois; Olivier Tillement; Jean-Luc Coll; Yannick Crémillieux
Journal:  MAGMA       Date:  2013-10-30       Impact factor: 2.310

4.  Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis.

Authors:  Christina Amaxopoulou; Ralph Gnannt; Kai Higashigaito; Andreas Jung; Christian J Kellenberger
Journal:  Pediatr Radiol       Date:  2017-11-15

5.  Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography.

Authors:  MingDe Lin; Craig T Marshall; Yi Qi; Samuel M Johnston; Cristian T Badea; Claude A Piantadosi; G Allan Johnson
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

6.  Ventilation/perfusion imaging in a rat model of airway obstruction.

Authors:  Nilesh N Mistry; Yi Qi; Laurence W Hedlund; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

7.  Oxygen enhanced MR ventilation imaging of the lung.

Authors:  Q Chen; P M Jakob; M A Griswold; D L Levin; H Hatabu; R R Edelman
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

8.  Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model.

Authors:  Cornelius Brinegar; Sarah S Schmitter; Nilesh N Mistry; G Allan Johnson; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

9.  Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

Authors:  Jessica M Oakes; Miriam Scadeng; Ellen C Breen; G Kim Prisk; Chantal Darquenne
Journal:  Ann Biomed Eng       Date:  2013-01-25       Impact factor: 3.934

10.  Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI.

Authors:  Nilesh N Mistry; James Pollaro; Jiayu Song; Ming De Lin; G Allan Johnson
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.