Literature DB >> 15844144

Quantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.

Stacie I Ringleb1, Qingshan Chen, David S Lake, Armando Manduca, Richard L Ehman, Kai-Nan An.   

Abstract

Magnetic resonance elastography (MRE), a phase contrast MRI technique, images the propagation of applied mechanical waves in tissue, allowing shear stiffness to be quantified in vivo. This MRE technique has been validated with static mechanical compression tests. Dynamic mechanical analysis (DMA) may be a more appropriate comparison to MRE because it directly measures the shear modulus dynamically, while compression tests convert the measured elastic modulus to shear modulus with an assumed Poisson ratio. This study compared the shear stiffness estimated with various MRE inversion algorithms (i.e., manual calculation, local frequency estimate, phase gradient, direct inversion, and matched filter) to the dynamic mechanical test. The shear stiffness of five agarose gels with concentrations ranging from 1.5 to 3.5% were measured using MRE and DMA. The phase gradient inversion algorithm overestimated the shear modulus at higher concentrations (i.e., 3-3.5% agar), while the results from the other techniques correlated well with the dynamic mechanical test. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15844144     DOI: 10.1002/mrm.20449

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Magnetic resonance elastography methodology for the evaluation of tissue engineered construct growth.

Authors:  Evan T Curtis; Simeng Zhang; Vahid Khalilzad-Sharghi; Thomas Boulet; Shadi F Othman
Journal:  J Vis Exp       Date:  2012-02-09       Impact factor: 1.355

2.  Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with magnetic resonance elastography (MRE).

Authors:  Gwladys E Leclerc; Laëtitia Debernard; Félix Foucart; Ludovic Robert; Kay M Pelletier; Fabrice Charleux; Richard Ehman; Marie-Christine Ho Ba Tho; Sabine F Bensamoun
Journal:  J Biomech       Date:  2012-01-28       Impact factor: 2.712

3.  Effects of frequency- and direction-dependent elastic materials on linearly elastic MRE image reconstructions.

Authors:  I M Perreard; A J Pattison; M Doyley; M D J McGarry; Z Barani; E E Van Houten; J B Weaver; K D Paulsen
Journal:  Phys Med Biol       Date:  2010-10-28       Impact factor: 3.609

4.  Magnetic resonance elastography compared with rotational rheometry for in vitro brain tissue viscoelasticity measurement.

Authors:  Jonathan Vappou; Elodie Breton; Philippe Choquet; Christian Goetz; Rémy Willinger; André Constantinesco
Journal:  MAGMA       Date:  2007-12-15       Impact factor: 2.310

5.  Congruence of imaging estimators and mechanical measurements of viscoelastic properties of soft tissues.

Authors:  Man Zhang; Benjamin Castaneda; Zhe Wu; Priya Nigwekar; Jean V Joseph; Deborah J Rubens; Kevin J Parker
Journal:  Ultrasound Med Biol       Date:  2007-07-02       Impact factor: 2.998

6.  Magnetic Resonance Measurement of Transient Shear Wave Propagation in a Viscoelastic Gel Cylinder.

Authors:  P V Bayly; P G Massouros; E Christoforou; A Sabet; G M Genin
Journal:  J Mech Phys Solids       Date:  2008-05       Impact factor: 5.471

7.  Diffraction-biased shear wave fields generated with longitudinal magnetic resonance elastography drivers.

Authors:  Meng Yin; Olivier Rouvière; Kevin J Glaser; Richard L Ehman
Journal:  Magn Reson Imaging       Date:  2008-05-07       Impact factor: 2.546

Review 8.  Abdominal magnetic resonance elastography.

Authors:  Meng Yin; Jun Chen; Kevin J Glaser; Jayant A Talwalkar; Richard L Ehman
Journal:  Top Magn Reson Imaging       Date:  2009-04

9.  Ability of magnetic resonance elastography to assess taut bands.

Authors:  Qingshan Chen; Jeffrey Basford; Kai-Nan An
Journal:  Clin Biomech (Bristol, Avon)       Date:  2008-02-21       Impact factor: 2.063

10.  Shearwave dispersion ultrasound vibrometry (SDUV) on swine kidney.

Authors:  Carolina Amador; Matthew W Urban; Shigao Chen; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.