Literature DB >> 15843726

The use of the Levenberg-Marquardt curve-fitting algorithm in pharmacokinetic modelling of DCE-MRI data.

T S Ahearn1, R T Staff, T W Redpath, S I K Semple.   

Abstract

The use of curve-fitting and compartmental modelling for calculating physiological parameters from measured data has increased in popularity in recent years. Finding the 'best fit' of a model to data involves the minimization of a merit function. An example of a merit function is the sum of the squares of the differences between the data points and the model estimated points. This is facilitated by curve-fitting algorithms. Two curve-fitting methods, Levenberg-Marquardt and MINPACK-1, are investigated with respect to the search start points that they require and the accuracy of the returned fits. We have simulated one million dynamic contrast enhanced MRI curves using a range of parameters and investigated the use of single and multiple search starting points. We found that both algorithms, when used with a single starting point, return unreliable fits. When multiple start points are used, we found that both algorithms returned reliable parameters. However the MINPACK-1 method generally outperformed the Levenberg-Marquardt method. We conclude that the use of a single starting point when fitting compartmental modelling data such as this produces unsafe results and we recommend the use of multiple start points in order to find the global minima.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15843726     DOI: 10.1088/0031-9155/50/9/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  An expectation-maximisation approach for simultaneous pixel classification and tracer kinetic modelling in dynamic contrast enhanced-magnetic resonance imaging.

Authors:  Mario Sansone; Roberta Fusco; Antonella Petrillo; Mario Petrillo; Marcello Bracale
Journal:  Med Biol Eng Comput       Date:  2010-11-03       Impact factor: 2.602

Review 2.  Analysis of contrast-enhanced MR images to assess renal function.

Authors:  N Michoux; J-P Vallée; A Pechère-Bertschi; X Montet; L Buehler; B E Van Beers
Journal:  MAGMA       Date:  2006-08-12       Impact factor: 2.310

3.  Evaluation of the effect of transcytolemmal water exchange analysis for therapeutic response assessment using DCE-MRI: a comparison study.

Authors:  Chunhao Wang; Ergys Subashi; Xiao Liang; Fang-Fang Yin; Zheng Chang
Journal:  Phys Med Biol       Date:  2016-06-08       Impact factor: 3.609

Review 4.  Review of treatment assessment using DCE-MRI in breast cancer radiation therapy.

Authors:  Chun-Hao Wang; Fang-Fang Yin; Janet Horton; Zheng Chang
Journal:  World J Methodol       Date:  2014-06-26

Review 5.  Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer.

Authors:  Michael Ingrisch; Steven Sourbron
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-04-06       Impact factor: 2.745

6.  Robust and efficient pharmacokinetic parameter non-linear least squares estimation for dynamic contrast enhanced MRI of the prostate.

Authors:  Soudabeh Kargar; Eric A Borisch; Adam T Froemming; Akira Kawashima; Lance A Mynderse; Eric G Stinson; Joshua D Trzasko; Stephen J Riederer
Journal:  Magn Reson Imaging       Date:  2017-12-24       Impact factor: 2.546

7.  Bolus arrival time and its effect on tissue characterization with dynamic contrast-enhanced magnetic resonance imaging.

Authors:  Alireza Mehrtash; Sandeep N Gupta; Dattesh Shanbhag; James V Miller; Tina Kapur; Fiona M Fennessy; Ron Kikinis; Andriy Fedorov
Journal:  J Med Imaging (Bellingham)       Date:  2016-03-01

8.  Comparison of region-of-interest-averaged and pixel-averaged analysis of DCE-MRI data based on simulations and pre-clinical experiments.

Authors:  Dianning He; Marta Zamora; Aytekin Oto; Gregory S Karczmar; Xiaobing Fan
Journal:  Phys Med Biol       Date:  2017-09-05       Impact factor: 3.609

9.  A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution.

Authors:  Julio Cárdenas-Rodríguez; Christine M Howison; Mark D Pagel
Journal:  Magn Reson Imaging       Date:  2012-12-08       Impact factor: 2.546

10.  The impact of parameter identification methods on drug therapy control in an intensive care unit.

Authors:  Christopher E Hann; J Geoffrey Chase; Michael F Ypma; Jos Elfring; Noorhafiz Mohd Nor; Piers Lawrence; Geoffrey M Shaw
Journal:  Open Med Inform J       Date:  2008-05-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.