Literature DB >> 15842427

Magnetocardiogram recordings in a nonshielded environment--reproducibility and ischemia detection.

Benjamin A Steinberg1, Ariel Roguin, Stanley P Watkins, Peter Hill, Dharsh Fernando, Jon R Resar.   

Abstract

BACKGROUND: Magnetocardiography (MCG) is a noninvasive technology that measures the magnetic field of the heart by superconducting quantum interference devices (SQUID) sensors. The novelty of the present system is that the sensors can be operated without electromagnetic shielding of the examination room, thus allowing the system to be easily installed in the emergency department or chest pain unit. Studies in shielded rooms, found that this imaging modality may have better sensitivity as compared to ECG in detecting ischemia. We aimed (1) to assess the reproducibility, intra-observer, and interobserver interpretation variability and (2) to assess the MCG maps in the presence of coronary narrowings. METHODS AND
RESULTS: All measurements were performed in a nonshielded room. For the first part of the study, two MCG maps were recorded in 24 otherwise healthy volunteers (age 20-44 years, median 24, 16 male) in an interval ranging from 2 to 48 hours. The maps were interpreted using the CardioMag software for contour maps, averaged MCG time traces, and waveform morphology of repolarization by two observers blinded to each other. The parameters tested had low disagreement between repeated measurements. The correlations of the intra-observer and interobserver interpretation were excellent. Secondly, MCG maps were obtained in 29 patients referred for angiography due to suspected coronary artery disease. Nineteen of them had coronary narrowings defined as more than 50%. In this group, 16 (84.2%) had abnormal MCG maps as compared to only 5 (26.3%) who had abnormal ECGs (P < 0.01).
CONCLUSIONS: MCG maps can be successfully obtained in a nonshielded room and allow feasible, accurate, and reproducible measurements with little intra-observer and interobserver variability. Ischemic changes in the heart's magnetic field may occur before electrical changes. Our pilot data suggests that this imaging modality may potentially offer better sensitivity as compared to rest ECG in detecting ischemia in a cohort of patients who had coronary narrowings identified by angiography.

Entities:  

Mesh:

Year:  2005        PMID: 15842427      PMCID: PMC6932464          DOI: 10.1111/j.1542-474X.2005.05611.x

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  8 in total

1.  Magnetocardiographic and electrocardiographic exercise mapping in healthy subjects.

Authors:  P Takala; H Hänninen; J Montone; M Mäkijärvi; J Nenonen; L Oikarinen; K Simeliu; L Toivonen; T Katil
Journal:  Ann Biomed Eng       Date:  2001-06       Impact factor: 3.934

2.  Reproducibility of HTS-SQUID magnetocardiography in an unshielded clinical environment.

Authors:  U Leder; F Schrey; J Haueisen; L Dörrer; J Schreiber; M Liehr; G Schwarz; O Solbrig; H R Figulla; P Seidel
Journal:  Int J Cardiol       Date:  2001-07       Impact factor: 4.164

3.  Magnetocardiography in coronary artery disease with a new system in an unshielded setting.

Authors:  Birgit Hailer; Illja Chaikovsky; Sabine Auth-Eisernitz; Harald Schäfer; Fritz Steinberg; Dietrich H W Grönemeyer
Journal:  Clin Cardiol       Date:  2003-10       Impact factor: 2.882

4.  DETECTION OF THE MAGNETIC FIELD OF THE HEART.

Authors:  G BAULE; R MCFEE
Journal:  Am Heart J       Date:  1963-07       Impact factor: 4.749

5.  An economic analysis of an aggressive diagnostic strategy with single photon emission computed tomography myocardial perfusion imaging and early exercise stress testing in emergency department patients who present with chest pain but nondiagnostic electrocardiograms: results from a randomized trial.

Authors:  S A Stowers; E L Eisenstein; F J Th Wackers; D S Berman; J L Blackshear; A D Jones; T J Szymanski; L C Lam; T A Simons; D Natale; K A Paige; G S Wagner
Journal:  Ann Emerg Med       Date:  2000-01       Impact factor: 5.721

6.  The fetal magnetocardiogram.

Authors:  V Kariniemi; J Ahopelto; P J Karp; T E Katila
Journal:  J Perinat Med       Date:  1974       Impact factor: 1.901

7.  A new screening method to diagnose coronary artery disease using multichannel magnetocardiogram and simple exercise.

Authors:  Hideaki Kanzaki; Satoshi Nakatani; Akihiko Kandori; Keiji Tsukada; Kunio Miyatake
Journal:  Basic Res Cardiol       Date:  2003-03       Impact factor: 17.165

8.  Features of ST segment and T-wave in exercise-induced myocardial ischemia evaluated with multichannel magnetocardiography.

Authors:  Helena Hänninen; Panu Takala; Petri Korhonen; Lasse Oikarinen; Markku Mäkijärvi; Jukka Nenonen; Toivo Katila; Lauri Toivonen
Journal:  Ann Med       Date:  2002       Impact factor: 4.709

  8 in total
  2 in total

1.  Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects.

Authors:  Anna Rita Sorbo; Gianmarco Lombardi; Lara La Brocca; Gianluigi Guida; Riccardo Fenici; Donatella Brisinda
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-12-20       Impact factor: 1.468

Review 2.  Magnetocardiography for the diagnosis of coronary artery disease: a systematic review and meta-analysis.

Authors:  Rajender Agarwal; Abhimanyu Saini; Tareq Alyousef; Craig A Umscheid
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-08-13       Impact factor: 1.468

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.