Investigation of secondary neutron dose for 18 MV dynamic MLC IMRT delivery.

Rebecca M Howell1, Michele S Ferenci, Nolan E Hertel, Gary D Fullerton.   

Abstract

Secondary neutron doses from the delivery of 18 MV conventional and intensity modulated radiation therapy (IMRT) treatment plans were compared. IMRT was delivered using dynamic multileaf collimation (MLC). Additional measurements were made with static MLC using a primary collimated field size of 10 x 10 cm2 and MLC field sizes of 0 x 0, 5 x 5, and 10 x 10 cm2. Neutron spectra were measured and effective doses calculated. The IMRT treatment resulted in a higher neutron fluence and higher dose equivalent. These increases were approximately the ratio of the monitor units. The static MLC measurements were compared to Monte Carlo calculations. The actual component dimensions and materials for the Varian Clinac 2100/2300C including the MLC were modeled with MCNPX to compute the neutron fluence due to neutron production in and around the treatment head. There is excellent agreement between the calculated and measured neutron fluence for the collimated field size of 10 x 10 cm2 with the 0 x 0 cm2 MLC field. Most of the neutrons at the detector location for this geometry are directly from the accelerator head with a small contribution from room scatter. Future studies are needed to investigate the effect of different beam energies used in IMRT incorporating the effects of scattered photon dose as well as secondary neutron dose.

Mesh:

Year:  2005        PMID: 15839351     DOI: 10.1118/1.1861162

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Secondary neutron spectrum from 250-MeV passively scattered proton therapy: measurement with an extended-range Bonner sphere system.

Authors:  Rebecca M Howell; E A Burgett
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

3.  Secondary radiation dose during high-energy total body irradiation.

Authors:  M Janiszewska; K Polaczek-Grelik; M Raczkowski; B Szafron; A Konefał; W Zipper
Journal:  Strahlenther Onkol       Date:  2014-03-06       Impact factor: 3.621

4.  Monte Carlo characterizations mapping of the (γ,n) and (n,γ) photonuclear reactions in the high energy X-ray radiation therapy.

Authors:  Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-31

5.  Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.

Authors:  Bryan Bednarz; X George Xu
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

Review 6.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

7.  Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom.

Authors:  Bryan Bednarz; Cindy Hancox; X George Xu
Journal:  Phys Med Biol       Date:  2009-08-11       Impact factor: 3.609

8.  Cephalometric assessment of the axial inclination of upper and lower incisors in relation to the third-order angle.

Authors:  Michael Knösel; Rengin Attin; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  J Orofac Orthop       Date:  2007-05       Impact factor: 1.938

Review 9.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

10.  Evaluation of equivalent dose from neutrons and activation products from a 15-MV X-ray LINAC.

Authors:  Isra Israngkul-Na-Ayuthaya; Sivalee Suriyapee; Phongpheath Pengvanich
Journal:  J Radiat Res       Date:  2015-08-11       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.