Comparison of inhomogeneity correction algorithms in small photon fields.

Andrew O Jones1, Indra J Das.   

Abstract

Algorithms such as convolution superposition, Batho, and equivalent pathlength which were originally developed and validated for conventional treatments under conditions of electronic equilibrium using relatively large fields greater than 5 x 5 cm2 are routinely employed for inhomogeneity corrections. Modern day treatments using intensity modulated radiation therapy employ small beamlets characterized by the resolution of the multileaf collimator. These beamlets, in general, do not provide electronic equilibrium even in a homogeneous medium, and these effects are exaggerated in media with inhomogenieties. Monte Carlo simulations are becoming a tool of choice in understanding the dosimetry of small photon fields as they encounter low density media. In this study, depth dose data from the Monte Carlo simulations are compared to the results of the convolution superposition, Batho, and equivalent pathlength algorithms. The central axis dose within the low-density inhomogeneity as calculated by Monte Carlo simulation and convolution superposition decreases for small field sizes whereas it increases using the Batho and equivalent pathlength algorithms. The dose perturbation factor (DPF) is defined as the ratio of dose to a point within the inhomogeneity to the same point in a homogeneous phantom. The dose correction factor is defined as the ratio of dose calculated by an algorithm at a point to the Monte Carlo derived dose at the same point, respectively. DPF is noted to be significant for small fields and low density for all algorithms. Comparisons of the algorithms with Monte Carlo simulations is reflected in the DCF, which is close to 1.0 for the convolution-superposition algorithm. The Batho and equivalent pathlength algorithms differ significantly from Monte Carlo simulation for most field sizes and densities. Convolution superposition shows better agreement with Monte Carlo data versus the Batho or equivalent pathlength corrections. As the field size increases the DCF's for all algorithms converge toward 1.0. The largest differences in DCF are at the interface where changes in electron transport are greatest. For a 6 MV photon beam, electronic equilibrium is restored at field sizes above 3 cm diameter and all of the algorithms predict dose in and beyond the inhomogeneous region equally well. For accurate dosimetry of small fields within and near inhomogeneities, however, simple algorithms such as Batho and equivalent pathlength should be avoided.

Entities:  

Mesh:

Year:  2005        PMID: 15839349     DOI: 10.1118/1.1861154

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  Dosimetric verification of the anisotropic analytical algorithm in lung equivalent heterogeneities with and without bone equivalent heterogeneities.

Authors:  Kaoru Ono; Satoru Endo; Kenichi Tanaka; Masaharu Hoshi; Yutaka Hirokawa
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

Authors:  Joao Seco; Greg C Sharp; Ziji Wu; David Gierga; Florian Buettner; Harald Paganetti
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  Technical note: Heterogeneity dose calculation accuracy in IMRT: study of five commercial treatment planning systems using an anthropomorphic thorax phantom.

Authors:  Scott E Davidson; Richard A Popple; Geoffrey S Ibbott; David S Followill
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors.

Authors:  Jianzhou Wu; Huiling Li; Raj Shekhar; Mohan Suntharalingam; Warren D'Souza
Journal:  Radiother Oncol       Date:  2008-03-24       Impact factor: 6.280

5.  On the quantification of the dosimetric accuracy of collapsed cone convolution superposition (CCCS) algorithm for small lung volumes using IMRT.

Authors:  Oscar I Calvo; Alonso N Gutiérrez; Sotirios Stathakis; Carlos Esquivel; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

6.  Dose measurements in a thorax phantom at 3DCRT breast radiation therapy.

Authors:  Elsa Bifano Pimenta; Luciana Batista Nogueira; Tarcísio Passos Ribeiro de Campos
Journal:  Rep Pract Oncol Radiother       Date:  2021-04-14

7.  A dosimetric phantom study of dose accuracy and build-up effects using IMRT and RapidArc in stereotactic irradiation of lung tumours.

Authors:  Jan Seppala; Sami Suilamo; Jarmo Kulmala; Pekka Mali; Heikki Minn
Journal:  Radiat Oncol       Date:  2012-05-31       Impact factor: 3.481

8.  Dosimetric accuracy of tomotherapy dose calculation in thorax lesions.

Authors:  Veronica Ardu; Sara Broggi; Giovanni Mauro Cattaneo; Paola Mangili; Riccardo Calandrino
Journal:  Radiat Oncol       Date:  2011-02-09       Impact factor: 3.481

9.  Effect of low-density heterogeneities in telecobalt therapy and validation of dose calculation algorithm of a treatment planning system.

Authors:  Anuj Kumar; Sunil Dutt Sharma; A K Arya; Surabhi Gupta; Deepak Shrotriya
Journal:  J Med Phys       Date:  2011-10

10.  Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose.

Authors:  Danny Schuring; Coen W Hurkmans
Journal:  Radiat Oncol       Date:  2008-07-28       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.