Literature DB >> 15839115

Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures.

Irene Herrmann1, Ulf Lekholm, Sture Holm, Christina Kultje.   

Abstract

PURPOSE: The purpose of this study was to evaluate patient, implant, and treatment characteristics to identify possible prognostic factors for implant failure.
MATERIALS AND METHODS: Out of a database with different dental implant treatment protocols, a research database of 1 randomly selected implant per patient was created. The database consisted of 487 implants. Of these, 80 were withdrawn, 36 failed, and 371 remained successful during a 5-year follow-up period. Potential risk factors were evaluated by chi-square tests and post hoc analyses.
RESULTS: Significant or strongly significant differences were found regarding implant failures as a result of jawbone quality, jaw shape, implant length, treatment protocol, and combinations of jawbone-related characteristics. Responsible clinics and number of implants supporting the restoration were factors that could not be associated with implant failure. DISCUSSION: Implant failures in this study were more often seen when negative patient-related factors were present. Approximately 65% of the patients with a combination of the 2 most negative bone-related factors (jawbone quality 4 and jaw shape D or E) experienced implant failure. However, only 3% of the patients had this combination. Implant length, the only implant-related factor evaluated, was also significantly correlated with the success rate, but implant length could also be regarded as a result of the jawbone volume available. Another negative patient-related factor was the treatment protocol; however, in most cases this was also indirectly or partly related to the status of the jawbone available for implant placement.
CONCLUSION: Patient selection appears to be of importance for increasing implant success rates.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15839115

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  36 in total

1.  Bone regeneration in dentistry.

Authors:  Paolo Tonelli; Marco Duvina; Luigi Barbato; Eleonora Biondi; Niccolò Nuti; Leila Brancato; Giovanna Delle Rose
Journal:  Clin Cases Miner Bone Metab       Date:  2011-09

2.  Stress distribution in the peri-implant bone with splinted and non-splinted implants by in vivo loading data-based finite element analysis.

Authors:  Ryuji Shigemitsu; Toru Ogawa; Tetsuya Matsumoto; Nobuhiro Yoda; Yoshinori Gunji; Yuki Yamakawa; Kiyohiro Ikeda; Keiichi Sasaki
Journal:  Odontology       Date:  2012-06-29       Impact factor: 2.634

3.  Predicting clustered dental implant survival using frailty methods.

Authors:  S-K Chuang; T Cai
Journal:  J Dent Res       Date:  2006-12       Impact factor: 6.116

Review 4.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

5.  Implant stability in different techniques of surgical sites preparation: an in vitro study.

Authors:  C Rastelli; G Falisi; R Gatto; M Galli; E Saccone; M Severino; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

Review 6.  Short Implants: New Horizon in Implant Dentistry.

Authors:  Neha Jain; Manisha Gulati; Meenu Garg; Chetan Pathak
Journal:  J Clin Diagn Res       Date:  2016-09-01

7.  Influence of cone beam CT scanning parameters on grey value measurements at an implant site.

Authors:  A Parsa; N Ibrahim; B Hassan; A Motroni; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

Review 8.  Osseodensification -- A systematic review and qualitative analysis of published literature.

Authors:  Ninad Milind Padhye; Ashvini Mukul Padhye; Neel B Bhatavadekar
Journal:  J Oral Biol Craniofac Res       Date:  2019-11-02

9.  The application of locking-taper implants in posterior area implant restoration with insufficient occlusal-gingival distances.

Authors:  Guoxi Sun; Lei Cao; Haiying Zhang
Journal:  Am J Transl Res       Date:  2021-06-15       Impact factor: 4.060

10.  Effect of rotation bump on removal torque of orthodontic mini-implants.

Authors:  Odontuya Gansukh; Jong-Wha Jeong; Jong-Wan Kim; Young-Kyun Kim; Jong-Ho Lee; Tae-Woo Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-12-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.