Literature DB >> 15831419

Statistical validation of brain tumor shape approximation via spherical harmonics for image-guided neurosurgery.

Daniel Goldberg-Zimring1, Ion-Florin Talos, Jui G Bhagwat, Steven J Haker, Peter M Black, Kelly H Zou.   

Abstract

RATIONALE AND
OBJECTIVES: Surgical planning now routinely uses both two-dimensional (2D) and three-dimensional (3D) models that integrate data from multiple imaging modalities, each highlighting one or more aspects of morphology or function. We performed a preliminary evaluation of the use of spherical harmonics (SH) in approximating the 3D shape and estimating the volume of brain tumors of varying characteristics.
MATERIALS AND METHODS: Magnetic resonance (MR) images from five patients with brain tumors were selected randomly from our MR-guided neurosurgical practice. Standardized mean square reconstruction errors (SMSRE) by tumor volume were measured. Validation metrics for comparing performances of the SH method against segmented contours (SC) were the dice similarity coefficient (DSC) and standardized Euclidean distance (SED) measure.
RESULTS: Tumor volume range was 22,413-85,189 mm3, and range of number of vertices in triangulated models was 3674-6544. At SH approximations with degree of at least 30, SMSRE were within 1.66 x 10(-5) mm(-1). Summary measures yielded a DSC range of 0.89-0.99 (pooled median, 0.97 and significantly >0.7; P < .001) and an SED range of 0.0002-0.0028 (pooled median, 0.0005).
CONCLUSION: 3D shapes of tumors may be approximated by using SH for neurosurgical applications.

Entities:  

Mesh:

Year:  2005        PMID: 15831419      PMCID: PMC1415223          DOI: 10.1016/j.acra.2004.11.032

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  7 in total

1.  On the Laplace-Beltrami operator and brain surface flattening.

Authors:  S Angenent; S Haker; A Tannenbaum; R Kikinis
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Parameter space warping: shape-based correspondence between morphologically different objects.

Authors:  Dominik Meier; Elizabeth Fisher
Journal:  IEEE Trans Med Imaging       Date:  2002-01       Impact factor: 10.048

3.  Assessment of multiple sclerosis lesions with spherical harmonics: comparison of MR imaging and pathologic findings.

Authors:  Daniel Goldberg-Zimring; Bruria Shalmon; Kelly H Zou; Haim Azhari; Dvora Nass; Anat Achiron
Journal:  Radiology       Date:  2005-04-15       Impact factor: 11.105

4.  3-D surface reconstruction of multiple sclerosis lesions using spherical harmonics.

Authors:  D Goldberg-Zimring; H Azhari; S Miron; A Achiron
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

5.  Three validation metrics for automated probabilistic image segmentation of brain tumours.

Authors:  Kelly H Zou; William M Wells; Ron Kikinis; Simon K Warfield
Journal:  Stat Med       Date:  2004-04-30       Impact factor: 2.373

6.  Three-dimensional analysis of the geometry of individual multiple sclerosis lesions: detection of shape changes over time using spherical harmonics.

Authors:  Daniel Goldberg-Zimring; Anat Achiron; Charles R G Guttmann; Haim Azhari
Journal:  J Magn Reson Imaging       Date:  2003-09       Impact factor: 4.813

7.  Statistical validation of image segmentation quality based on a spatial overlap index.

Authors:  Kelly H Zou; Simon K Warfield; Aditya Bharatha; Clare M C Tempany; Michael R Kaus; Steven J Haker; William M Wells; Ferenc A Jolesz; Ron Kikinis
Journal:  Acad Radiol       Date:  2004-02       Impact factor: 3.173

  7 in total
  11 in total

1.  Deformable registration of abdominal kilovoltage treatment planning CT and tomotherapy daily megavoltage CT for treatment adaptation.

Authors:  Deshan Yang; Summer R Chaudhari; S Murty Goddu; David Pratt; Divya Khullar; Joseph O Deasy; Issam El Naqa
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

2.  Classification of normal and diseased liver shapes based on Spherical Harmonics coefficients.

Authors:  Farshid Babapour Mofrad; Reza Aghaeizadeh Zoroofi; Ali Abbaspour Tehrani-Fard; Shahram Akhlaghpoor; Yoshinobu Sato
Journal:  J Med Syst       Date:  2014-04-24       Impact factor: 4.460

3.  Radiologic image-based statistical shape analysis of brain tumours.

Authors:  Karthik Bharath; Sebastian Kurtek; Arvind Rao; Veerabhadran Baladandayuthapani
Journal:  J R Stat Soc Ser C Appl Stat       Date:  2018-03-15       Impact factor: 1.864

4.  A quantitative study of shape descriptors from glioblastoma multiforme phenotypes for predicting survival outcome.

Authors:  Ahmad Chaddad; Christian Desrosiers; Lama Hassan; Camel Tanougast
Journal:  Br J Radiol       Date:  2016-10-26       Impact factor: 3.039

5.  Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method.

Authors:  He Wang; Adam S Garden; Lifei Zhang; Xiong Wei; Anesa Ahamad; Deborah A Kuban; Ritsuko Komaki; Jennifer O'Daniel; Yongbin Zhang; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

6.  Shape Features of the Lesion Habitat to Differentiate Brain Tumor Progression from Pseudoprogression on Routine Multiparametric MRI: A Multisite Study.

Authors:  M Ismail; V Hill; V Statsevych; R Huang; P Prasanna; R Correa; G Singh; K Bera; N Beig; R Thawani; A Madabhushi; M Aahluwalia; P Tiwari
Journal:  AJNR Am J Neuroradiol       Date:  2018-11-01       Impact factor: 3.825

7.  Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images.

Authors:  Wannapha Nobnop; Hudsaleark Neamin; Imjai Chitapanarux; Somsak Wanwilairat; Vicharn Lorvidhaya; Taweap Sanghangthum
Journal:  J Med Radiat Sci       Date:  2017-07-29

8.  Effect of Deformation Methods on the Accuracy of Deformable Image Registration From Kilovoltage CT to Tomotherapy Megavoltage CT.

Authors:  Wannapha Nobnop; Imjai Chitapanarux; Somsak Wanwilairat; Ekkasit Tharavichitkul; Vicharn Lorvidhaya; Patumrat Sripan
Journal:  Technol Cancer Res Treat       Date:  2019-01-01

9.  Exploration of Multiparameter Hematoma 3D Image Analysis for Predicting Outcome After Intracerebral Hemorrhage.

Authors:  Pascal Salazar; Mario Di Napoli; Mostafa Jafari; Alibay Jafarli; Wendy Ziai; Alexander Petersen; Stephan A Mayer; Eric M Bershad; Rahul Damani; Afshin A Divani
Journal:  Neurocrit Care       Date:  2020-04       Impact factor: 3.210

10.  Evaluation of Deformable Image Registration (DIR) Methods for Dose Accumulation in Nasopharyngeal Cancer Patients during Radiotherapy.

Authors:  Wannapha Nobnop; Imjai Chitapanarux; Hudsaleark Neamin; Somsak Wanwilairat; Vicharn Lorvidhaya; Taweap Sanghangthum
Journal:  Radiol Oncol       Date:  2017-09-15       Impact factor: 2.991

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.