Effects of scintillator on the modulation transfer function (MTF) of a digital imaging system.

Taeko T Farman1, Robert H Vandre, John C Pajak, Stuart R Miller, Alex Lempicki, Allan G Farman.   

Abstract

OBJECTIVE: To investigate the effects of 2 components (scintillator and x-ray generator) in the imaging chain on the modulation transfer function (MTF) of a charge-coupled device (CCD) digital intraoral radiographic system. STUDY
DESIGN: Three screens composed of 3 different scintillator materials, namely europium-doped lutetium oxide transparent optical ceramic (TOC), thallium-doped cesium iodide (CsI), and terbium-doped gadolinium oxysulfide (GOS), were compared. Each was used, in turn, in conjunction with a CCD detector having a pixel dimension of 19.5 mum. Two different x-ray generators were also used to evaluate this variable. MTF was investigated using the slanted slit method.
RESULTS: The TOC provided a good modulation response for low and middle frequencies, reducing to 0 only at a high cutoff frequency. With CsI and GOS, the system MTF dropped to 0 at a lower cutoff frequency than was the case with TOC. Hence, TOC provided higher spatial resolution than the other 2 scintillators tested under the experimental conditions applied. The differences in MTF attributed to the scintillator type were proportional and consistent.
CONCLUSIONS: Despite constant pixel dimensions, MTF was affected to a considerable degree by the scintillator applied and the x-ray generator used in conjunction with the same CCD imaging device. TOC shows potential as a possible replacement for CsI and GOS as a scintillator screen material for intraoral digital x-ray imaging using a solid-state detector, providing higher spatial resolution under the given experimental conditions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15829886     DOI: 10.1016/j.tripleo.2004.08.013

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  6 in total

Review 1.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

2.  The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.

Authors:  D D Brüllmann; B d'Hoedt
Journal:  Dentomaxillofac Radiol       Date:  2011-05       Impact factor: 2.419

3.  Effect of beam quality and readout direction in the edge profile on the modulation transfer function of photostimulable phosphor systems via the edge method.

Authors:  Shinya Takarabe; Taku Kuramoto; Yusuke Shibayama; Hiroki Tsuru; Masato Tatsumi; Toyoyuki Kato; Kazutoshi Okamura; Kazunori Yoshiura
Journal:  J Med Imaging (Bellingham)       Date:  2021-07-20

4.  Image resolution in the digital era: notion and clinical implications.

Authors:  Vahid Rakhshan
Journal:  J Dent (Shiraz)       Date:  2014-12

5.  Single-Crystalline Perovskite Nanowire Arrays for Stable X-ray Scintillators with Micrometer Spatial Resolution.

Authors:  Zhaojun Zhang; Hanna Dierks; Nils Lamers; Chen Sun; Klára Nováková; Crispin Hetherington; Ivan G Scheblykin; Jesper Wallentin
Journal:  ACS Appl Nano Mater       Date:  2021-12-18

6.  Effect of differences in pixel size on image characteristics of digital intraoral radiographic systems: a physical and visual evaluation.

Authors:  Taku Kuramoto; Shinya Takarabe; Kazutoshi Okamura; Kenshi Shiotsuki; Yusuke Shibayama; Hiroki Tsuru; Hiroshi Akamine; Masato Tatsumi; Toyoyuki Kato; Junji Morishita; Kazunori Yoshiura
Journal:  Dentomaxillofac Radiol       Date:  2020-05-07       Impact factor: 2.419

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.