Literature DB >> 15817364

Impact of IMRT and leaf width on stereotactic body radiotherapy of liver and lung lesions.

Pavel Dvorak1, Dietmar Georg, Joachim Bogner, Bernhard Kroupa, Karin Dieckmann, Richard Pötter.   

Abstract

PURPOSE: The present study explored the impact of intensity-modulated radiotherapy (IMRT) on stereotactic body RT (SBRT) of liver and lung lesions. Additionally, because target dose conformity can be affected by the leaf width of a multileaf collimator (MLC), especially for small targets and stereotactic applications, the use of a micro-MLC on "uniform intensity" conformal and intensity-modulated SBRT was evaluated. METHODS AND MATERIALS: The present study included 10 patients treated previously with SBRT in our institution (seven lung and three liver lesions). All patients were treated with 3 x 12 Gy prescribed to the 65% isodose level. The actual MLC-based conformal treatment plan served as the standard for additional comparison. In total, seven alternative treatment plans were made for each patient: a standard (actual) plan and an IMRT plan, both calculated with Helax TMS (Nucletron) using a pencil beam model; and a recalculated standard and a recalculated IMRT plan on Helax TMS using a point dose kernel approach. These four treatment plans were based on a standard MLC with 1-cm leaf width. Additionally, the following micro-MLC (central leaf width 3 mm)-based treatment plans were calculated with the BrainSCAN (BrainLAB) system: standard, IMRT, and dynamic arc treatments. For each treatment plan, various target parameters (conformity, coverage, mean, maximal, and minimal target dose, equivalent uniform doses, and dose-volume histogram), as well as organs at risk parameters (3 Gy and 6 Gy volume, mean dose, dose-volume histogram) were evaluated. Finally, treatment efficiency was estimated from monitor units and the number of segments for IMRT solutions.
RESULTS: For both treatment planning systems, no significant difference could be observed in terms of target conformity between the standard and IMRT dose distributions. All dose distributions obtained with the micro-MLC showed significantly better conformity values compared with the standard and IMRT plans using a regular MLC. Dynamic arc plans were characterized by the steepest dose gradient and thus the smallest V(6 Gy) values, which were on average 7% smaller than the standard plans and 20% lower than the IMRT plans. Although the Helax TMS IMRT plans show about 18% more monitor units than the standard plan, BrainSCAN IMRT plans require approximately twice the number of monitor units relative to the standard plan. All treatment plans optimized with a pencil beam model but recalculated with a superposition method showed significant qualitative, as well as quantitative, differences, especially with respect to conformity and the dose to organs at risk.
CONCLUSION: Standard conformal treatment techniques for SBRT could not be improved with inversely planned IMRT approaches. Dose calculation algorithms applied in optimization modules for IMRT applications in the thoracic region need to be based on the most accurate dose calculation algorithms, especially when using higher energy photon beams.

Entities:  

Mesh:

Year:  2005        PMID: 15817364     DOI: 10.1016/j.ijrobp.2004.12.075

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  17 in total

1.  Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery.

Authors:  J A Tanyi; C M Kato; Y Chen; Z Chen; M Fuss
Journal:  Br J Radiol       Date:  2010-10-05       Impact factor: 3.039

2.  Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique.

Authors:  Shuri Aoki; Hideomi Yamashita; Akihiro Haga; Kanabu Nawa; Toshikazu Imae; Wataru Takahashi; Osamu Abe; Keiichi Nakagawa
Journal:  Oncol Lett       Date:  2018-01-16       Impact factor: 2.967

3.  Clinical effect of multileaf collimator width on the incidence of late rectal bleeding after high-dose intensity-modulated radiotherapy for localized prostate carcinoma.

Authors:  Haruo Inokuchi; Takashi Mizowaki; Yoshiki Norihisa; Kenji Takayama; Itaru Ikeda; Kiyonao Nakamura; Mitsuhiro Nakamura; Masahiro Hiraoka
Journal:  Int J Clin Oncol       Date:  2015-07-12       Impact factor: 3.402

4.  Stereotactic body radiation therapy (SBRT) for adrenal metastases : a feasibility study of advanced techniques with modulated photons and protons.

Authors:  Marta Scorsetti; Pietro Mancosu; Piera Navarria; Angelo Tozzi; Simona Castiglioni; Elena Clerici; Giacomo Reggiori; Francesca Lobefalo; Antonella Fogliata; Luca Cozzi
Journal:  Strahlenther Onkol       Date:  2011-03-25       Impact factor: 3.621

5.  A planning comparison of dynamic IMRT for different collimator leaf thicknesses with helical tomotherapy and RapidArc for prostate and head and neck tumors.

Authors:  Vesna Jacob; Wolfgang Bayer; Sabrina T Astner; R Busch; Peter Kneschaurek
Journal:  Strahlenther Onkol       Date:  2010-08-30       Impact factor: 3.621

6.  Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study.

Authors:  James A Tanyi; Paige A Summers; Charles L McCracken; Yiyi Chen; Li-Chung Ku; Martin Fuss
Journal:  Radiat Oncol       Date:  2009-07-10       Impact factor: 3.481

7.  IMRT/VMAT dose distributions generated for HD ® and Millennium ® collimators TrueBeam ® and Clinac ® accelerators.

Authors:  Krzysztof Ślosarek; Iwona Brąclik; Wojciech Leszczyński; Joanna Kopczyńska; Wojciech Osewski; Jacek Wendykier
Journal:  Rep Pract Oncol Radiother       Date:  2018-10-10

8.  Comparison of simple and complex liver intensity modulated radiotherapy.

Authors:  Mark T Lee; Thomas G Purdie; Cynthia L Eccles; Michael B Sharpe; Laura A Dawson
Journal:  Radiat Oncol       Date:  2010-11-30       Impact factor: 3.481

9.  Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer.

Authors:  Youling Gong; Shichao Wang; Lin Zhou; Yongmei Liu; Yong Xu; You Lu; Sen Bai; Yuchuan Fu; Qingfeng Xu; Qingfeng Jiang
Journal:  Radiat Oncol       Date:  2010-07-15       Impact factor: 3.481

10.  Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions.

Authors:  Q Jackie Wu; Zhiheng Wang; John P Kirkpatrick; Zheng Chang; Jeffrey J Meyer; Mei Lu; Calvin Huntzinger; Fang-Fang Yin
Journal:  Radiat Oncol       Date:  2009-01-21       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.