L Büermann1, M Krumrey, M Haney, E Schmid.
Abstract
We examined the production of dicentrics in human lymphocytes irradiated with 29 kV X-rays to a depth of 13.5 mm in a PMMA phantom. For these irradiation conditions, which are appropriate for the diagnostic application of mammography X-rays, a coefficient alpha of (5.88+/-0.66) x 10(-2) Gy(-1) of the linear quadratic dose-response relationship was determined. This value does not differ significantly from the coefficient alpha of (6.55+/-0.97) x 10(-2) Gy(-1) obtained earlier for a free-in-air set-up using blood of the same donor. The results are interpreted in terms of both the energy distributions of the photon fluence of mammography X-rays free-in-air and those in the PMMA phantom. Based on earlier results of experiments with monochromatic X-rays in the energy range 1.83-40 keV (completed here by an additional measurement at 25 keV), a fit function alpha(E) to the measured alpha coefficients as a function of the energy E of monochromatic X-rays was used to calculate weighted mean values alpha for both the mammography X-ray spectra free-in-air and in the phantom. As a result, weighted mean values of (4.9+/-1.0) x 10(-2) Gy(-1) and (4.5+/-1.0) x 10(-2) Gy(-1) were obtained, respectively. Although the measured alpha coefficients for mammography X-rays appear to be systematically higher than those calculated as weighted mean values alpha, it can be concluded that the modification of the mammography X-ray spectrum to a depth of 13.5 mm in a PMMA phantom compared with the free-in-air spectrum has no significant influence on the dicentric yields in human lymphocytes.Entities:
Mesh:
Year: 2005 PMID: 15812657 DOI: 10.1007/s00411-005-0273-z
Source DB: PubMed Journal: Radiat Environ Biophys ISSN: 0301-634X Impact factor: 1.925