Literature DB >> 15811746

Intraocular lens calculations after refractive surgery.

Robert A Latkany1, Amit R Chokshi, Mark G Speaker, Jodi Abramson, Barrie D Soloway, Guopei Yu.   

Abstract

PURPOSE: To evaluate the effect of refractive surgery on intraocular lens (IOL) power calculation, compare methods of IOL power calculation after refractive surgery, evaluate the effect of pre-refractive surgery refractive error on IOL deviation, review the literature on determining IOL power after refractive surgery, and introduce a formula for IOL calculation for use after refractive surgery for myopia.
SETTING: Laser & Corneal Surgery Associates and Center for Ocular Tear Film Disorders, New York, New York, USA.
METHODS: This retrospective noncomparative case series comprised 21 patients who had uneventful cataract extraction and IOL implantation after previous uneventful myopic refractive surgery. Six methods of IOL calculation were used: clinical history (IOL(HisK)), clinical history at the spectacle plane (IOL(HisKs)), vertex (IOL(vertex)), back-calculated (IOL(BC)), calculation based on average keratometry (IOL(avgK)), and calculation based on flattest keratometry (IOL(flatK)). Each method result was compared to an "exact" IOL (IOL(exact)) that would have resulted in emmetropia and then compared to the pre-refractive surgery manifest refraction using linear regression. The paired t test was used to determine statistical significance.
RESULTS: The IOL(HisKs) was the most accurate method for IOL calculations, with a mean deviation from emmetropia of -0.56 diopter +/-1.59 (D), followed by the IOL(BC) (+1.06 +/- 1.51 D), IOL(vertex) (+1.51 +/- 1.95 D), IOL(flatK) (-1.72 +/- 2.19 D), IOL(HisK) (-1.76 +/- 1.76 D), and IOL(avgK) (-2.32 +/- 2.36 D). There was no statistical difference between IOL(HisKs) and IOL(exact) in myopic eyes. The power of IOL(flatK) would be inaccurate by -(0.47x+0.85), where x is the pre-refractive surgery myopic SE (SEQ(m)). Thus, without adjusting IOL(flatK), most patients would be left hyperopic. However, when IOL(flatK) is adjusted with this formula, it would not be statistically different from IOL(exact).
CONCLUSIONS: For IOL power selection in previously myopic patients, a predictive formula to calculate IOL power based only on the pre-refractive surgery SEQ(m) and current flattest keratometry readings was not statistically different from IOL(exact). The IOL(HisKs), which was also not statistically different from IOL(exact), requires pre-refractive surgery keratometry readings that are often not available to the cataract surgeon.

Entities:  

Mesh:

Year:  2005        PMID: 15811746     DOI: 10.1016/j.jcrs.2004.06.053

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  18 in total

1.  Practical method to calculate post-LASIK corneal power: the Actual K(a+p) method.

Authors:  Yi-Qian Hu; Xiang-Yu Ye; Xiu-Li Zhou; Yin Li; Cheng-Hui Xu; Lin-Lu Tian; Huang Zhu; Yao-Hua Sheng
Journal:  Int J Ophthalmol       Date:  2010-12-18       Impact factor: 1.779

2.  Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  Saudi J Ophthalmol       Date:  2012-01

3.  Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes.

Authors:  Yanjun Hua; Chao Pan; Qinmei Wang
Journal:  Int Ophthalmol       Date:  2019-03-01       Impact factor: 2.031

4.  An intraocular lens power calculation formula based on optical coherence tomography: a pilot study.

Authors:  Maolong Tang; Yan Li; David Huang
Journal:  J Refract Surg       Date:  2010-06-17       Impact factor: 3.573

5.  Ray tracing software for intraocular lens power calculation after corneal excimer laser surgery.

Authors:  Megumi Saiki; Kazuno Negishi; Naoko Kato; Hidemasa Torii; Murat Dogru; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2014-02-25       Impact factor: 2.447

Review 6.  Clinically relevant biometry.

Authors:  Afsun Sahin; Pedram Hamrah
Journal:  Curr Opin Ophthalmol       Date:  2012-01       Impact factor: 3.761

7.  Optical coherence tomography accurately measures corneal power change from laser refractive surgery.

Authors:  Ryan P McNabb; Sina Farsiu; Sandra S Stinnett; Joseph A Izatt; Anthony N Kuo
Journal:  Ophthalmology       Date:  2014-12-06       Impact factor: 12.079

8.  Cataract Surgery After Refractive Surgery.

Authors:  Ravi H Patel; Carol L Karp; Sonia H Yoo; Guillermo Amescua; Anat Galor
Journal:  Int Ophthalmol Clin       Date:  2016

9.  Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis).

Authors:  David Huang; Maolong Tang; Li Wang; Xinbo Zhang; Rebecca L Armour; Devin M Gattey; Lorinna H Lombardi; Douglas D Koch
Journal:  Trans Am Ophthalmol Soc       Date:  2013-09

10.  Comparison of retinal image quality with spherical and customized aspheric intraocular lenses.

Authors:  Huanqing Guo; Alexander V Goncharov; Chris Dainty
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.