Literature DB >> 15798825

Reproducibility of sterilized rubber impressions.

Khalid M Abdelaziz1, Ahmed M Hassan, J S Hodges.   

Abstract

Impressions, dentures and other dental appliances may be contaminated with oral micro-flora or other organisms of varying pathogenicity from patient's saliva and blood. Several approaches have been tried to control the transmission of infectious organisms via dental impressions and because disinfection is less effective and has several drawbacks for impression characterization, several sterilization methods have been suggested. This study evaluated the reproducibility of rubber impressions after sterilization by different methods. Dimensional accuracy and wettability of two rubber impression materials (vinyl polysiloxane and polyether) were evaluated after sterilization by each of three well-known methods (immersion in 2% glutaraldehyde for 10 h, autoclaving and microwave radiation). Non-sterilized impressions served as control. The effect of the tray material on impression accuracy and the effect of topical surfactant on the wettability were also evaluated. One-way ANOVA with Dunnett's method was used for statistical analysis. All sterilizing methods reduced the reproducibility of rubber impressions, although not always significantly. Microwave sterilization had a small effect on both accuracy and wettability. The greater effects of the other methods could usually be overcome by using ceramic trays and by spraying impression surfaces with surfactant before pouring the gypsum mix. There was one exception: glutaraldehyde still degraded dimensional accuracy even with ceramic trays and surfactant. We conclude that a) sterilization of rubber impressions made on acrylic trays was usually associated with a degree of dimensional change; b) microwave energy seems to be a suitable technique for sterilizing rubber impressions; c) topical surfactant application helped restore wettability of sterilized impressions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15798825     DOI: 10.1590/s0103-64402004000300009

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  8 in total

1.  Evaluation of dimensional stability and accuracy of autoclavable polyvinyl siloxane impression material.

Authors:  Subash M Reddy; D Vijitha; S Karthikeyan; R Balasubramanian; A Satish
Journal:  J Indian Prosthodont Soc       Date:  2012-08-07

2.  Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions.

Authors:  A S Mahalakshmi; Vidhya Jeyapalan; Vallabh Mahadevan; Chitra Shankar Krishnan; N S Azhagarasan; Hariharan Ramakrishnan
Journal:  J Indian Prosthodont Soc       Date:  2019 Jan-Mar

3.  The accuracy of gypsum casts obtained from the disinfected extended-pour alginate impressions through prolonged storage times.

Authors:  Rania A Sharif; Khalid M Abdelaziz; Najla M Alshahrani; Fatimah S Almutairi; Mohrah A Alaseri; Hoda L Abouzeid; Mohamed F A Elagib
Journal:  BMC Oral Health       Date:  2021-06-09       Impact factor: 2.757

4.  Orthodontic instrument sterilization with microwave irradiation.

Authors:  Arif Yezdani; Krishnan Mahalakshmi; Kesavaram Padmavathy
Journal:  J Pharm Bioallied Sci       Date:  2015-04

5.  Comparative evaluation of elastic recovery of three different elastomeric impression materials on chemical disinfection and autoclaving: An in vitro study.

Authors:  Garima Gothwal; Sudhir Meena; U Narendra Padiyar; Hemant Kumar Sharma; Pragati Kaurani; Devendra Pal Singh
Journal:  J Indian Prosthodont Soc       Date:  2019-10-10

6.  3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions.

Authors:  Kuei-Ling Hsu; Abdulrahman A Balhaddad; Isadora Martini Garcia; Fabrício Mezzomo Collares; Vineet Dhar; Louis DePaola; Mary Anne Melo
Journal:  Saudi Dent J       Date:  2020-12-10

7.  The effect of disinfection with sodium hypochlorite 0.5% on dimensional stability of condensation silicone impression materials of speedex and irasil.

Authors:  Mohammad Hasan Kalantari; Afsaneh Malekzadeh; Ameneh Emami
Journal:  J Dent (Shiraz)       Date:  2014-09

8.  Dimensional stability of two impression materials after a 6-month storage period.

Authors:  Francisco Martins; Patrícia Branco; José Reis; Ignacio Barbero Navarro; Paulo Maurício
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.